Surface imaging‐based analysis of intrafraction motion for breast radiotherapy patients

نویسندگان

  • David B. Wiant
  • Stacy Wentworth
  • Jacqueline M. Maurer
  • Caroline L. Vanderstraeten
  • Jonathon A. Terrell
  • Benjamin J. Sintay
چکیده

Breast treatments are becoming increasingly complex as the use of modulated and partial breast therapies becomes more prevalent. These methods are predicated on accurate and precise positioning for treatment. However, the ability to quantify intrafraction motion has been limited by the excessive dose that would result from continuous X-ray imaging throughout treatment. Recently, surface imaging has offered the opportunity to obtain 3D measurements of patient position throughout breast treatments without radiation exposure. Thirty free-breathing breast patients were monitored with surface imaging for 831 monitoring sessions. Mean translations and rotations were calculated over each minute, each session, and over all sessions combined. The percentage of each session that the root mean squares (RMS) of the linear translations were outside of defined tolerances was determined for each patient. Correlations between mean translations per minute and time, and between standard deviation per minute and time, were evaluated using Pearson's r value. The mean RMS translation averaged over all patients was 2.39 mm ± 1.88 mm. The patients spent an average of 34%, 17%, 9%, and 5% of the monitoring time outside of 2 mm, 3 mm, 4 mm, and 5 mm RMS tolerances, respectively. The RMS values averaged over all patients were 2.71 mm ± 1.83 mm, 2.76 ± 2.27, and 2.98 mm ± 2.30 mm over the 5th, 10th, and 15th minutes of monitoring, respectively. The RMS values (r = 0.73, p = 0) and standard deviations (r = 0.88, p = 0) over all patients showed strong significant correlations with time. We see that the majority of patients' treatment time is spent within 5 mm of the isocenter and that patient position drifts with increasing treatment time. Treatment length should be consid- ered in the planning process. An 8 mm margin on a target volume would account for 2 SDs of motion for a treatment up to 15 minutes in length. 

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prostate Intrafraction Motion Assessed by Simultaneous Kv

PROSTATE INTRAFRACTION MOTION ASSESSED BY SIMULTANEOUS KV FLUOROSCOPY AT MV DELIVERY by JUSTUS D. ADAMSON August 2009 Co-Advisor: Dr. Qiuwen Wu Co-Advisor: Dr. Jay Burmeister Major: Medical Physics Degree: Doctor of Philosophy Purpose: To investigate the use of a gantry mounted kV imager for prostate intrafraction motion measurement during simultaneous dose delivery. Materials & Methods: We dev...

متن کامل

Assessment of planning target volume margins for intensity-modulated radiotherapy of the prostate gland: role of daily inter- and intrafraction motion.

PURPOSE To determine planning target volume margins for prostate intensity-modulated radiotherapy based on inter- and intrafraction motion using four daily localization techniques: three-point skin mark alignment, volumetric imaging with bony landmark registration, volumetric imaging with implanted fiducial marker registration, and implanted electromagnetic transponders (beacons) detection. M...

متن کامل

Inter- and intrafraction uncertainty in prostate bed image-guided radiotherapy.

PURPOSE The goals of this study were to measure inter- and intrafraction setup error and prostate bed motion (PBM) in patients undergoing post-prostatectomy image-guided radiotherapy (IGRT) and to propose appropriate population-based three-dimensional clinical target volume to planning target volume (CTV-PTV) margins in both non-IGRT and IGRT scenarios. METHODS AND MATERIALS In this prospecti...

متن کامل

Real‐time intrafraction prostate motion during linac based stereotactic radiotherapy with rectal displacement

BACKGROUND Kilovoltage Intrafraction Monitoring (KIM) is a method which determines the three-dimensional position of the prostate from two-dimensional kilovoltage (kV) projections taken during linac based radiotherapy treatment with real-time feedback. Rectal displacement devices (RDDs) allow for improved rectal dosimetry during prostate cancer treatment. This study used KIM to perform a prelim...

متن کامل

Real-time prostate motion assessment: image-guidance and the temporal dependence of intra-fraction motion

BACKGROUND The rapid adoption of image-guidance in prostate intensity-modulated radiotherapy (IMRT) results in longer treatment times, which may result in larger intrafraction motion, thereby negating the advantage of image-guidance. This study aims to qualify and quantify the contribution of image-guidance to the temporal dependence of intrafraction motion during prostate IMRT. METHODS One-h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014