Viable System Phenomena of Sfcl and Protective Coordination for Smart Grid Applications

نویسندگان

  • G. Vijaya Kumar
  • Prakash Kumar
چکیده

This paper proposes the possible effect on the reduction of fault current and its protective coordination for upcoming smart grid. Fault levels in electrical distribution system are rising due to the increasing presence of distributed generation, and this rising trend is expected to continue in the future. Superconducting fault current limiter is a promising electrical equipment to reduce the excessive fault current in electrical power system effectively. This paper describes the optimal positioning of SFCL for which a resistive type SFCL model was implemented and protective coordination was investigated. In addition a typical smart grid model including a distributed generation of Photovoltaic model was designed to determine the performance of SFCL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing and Analysis of Power System with SFCL Module

In most highly developed electrical power system, there are several difficulties related from generation to distribution. Usually, power generation is located at remote area from the load center. Long transmission and distribution lines have to be constructed and maintained to meet required reliability, power quality and economic point of views. Reliable, cheap, efficient conductor is required ...

متن کامل

Analysis on protection coordination of protective devices with a fault current limiter in the application location of a dispersed generation

As one of the solution of the increase problem of the fault current in a power system, the superconducting fault current limiter (SFCL) has been noticed as the attractive device because it has no power loss in a normal time and can limit the fault current rapidly without additional device to detect the fault current. However, the introduction of the SFCL in a power distribution system affects t...

متن کامل

Mitigation of Distributed Generation Impact on Protective Devices in a Distribution Network by Superconducting Fault Current Limiter

Protection of radial distribution networks is widely based on coordinated inverse time overcurrent relays (OCRs) ensuring both effectiveness and selectivity. However, the integration of distributed generation (DG) into an existing distribution network not only inevitably increases fault current levels to levels that may exceed the OCR ratings, but it may also disturb the original overcurrent re...

متن کامل

Coordination between Substation Area Backup Protection and Flux-Coupling Type Superconducting Fault Current Limiter Considering Network Communications

Since the interactivity, integrality and instantaneity of information communication in smart substation have been improved to higher levels, it can contribute to promote the realization of a centralized type substation area backup protection (SABP), acting as an integrated protection system for whole substation. On the side, in the case that fault current limiters (FCLs) are suggested to be emp...

متن کامل

A Lightweight Privacy-preserving Authenticated Key Exchange Scheme for Smart Grid Communications

Smart grid concept is introduced to modify the power grid by utilizing new information and communication technology. Smart grid needs live power consumption monitoring to provide required services and for this issue, bi-directional communication is essential. Security and privacy are the most important requirements that should be provided in the communication. Because of the complex design of s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012