Proton chemical shift imaging in pick complex.

نویسندگان

  • Osamu Kizu
  • Kei Yamada
  • Tsunehiko Nishimura
چکیده

BACKGROUND AND PURPOSE Pick complex (PC) is the name given to a group of diseases comprising Pick disease and its variations, all of which have a large degree of pathologic and clinical overlap. Because of this overlap, the observation of neuropathologic changes in vivo is difficult, although these changes play important roles in the criteria used for classification. The purpose of this study was to evaluate changes in brain metabolism in PC with proton chemical shift imaging ((1)H-CSI). METHODS Nine patients with PC (three each with frontotemporal dementia, corticobasal degeneration [CBD], and primary progressive aphasia [PPA]) and five healthy subjects underwent (1)H-CSI. Volumes of interest were selected at the level of the basal ganglia by using a spin-echo sequence (TR/TE, 2000/13). Peak areas and ratios of N-acetylaspartate (NAA), creatine (Cr), and choline (Cho) were calculated in voxels in the basal ganglia and perisylvian regions. RESULTS Reduced NAA/Cho ratios were observed in the right basal ganglia of the patients with PC. In patients with CBD or PPA, low NAA/Cr values were detected in the right perisylvian region. CONCLUSION In PC, (1)H-CSI decreased NAA values in a wide area. Significantly reduced NAA levels in the right hemisphere in patients with PC suggests a neurodegenerative change and may reflect cases in which the right hemisphere is dominantly affected, compared with the left hemisphere. (1)H-CSI provided information that could not be obtained with other imaging techniques. Thus, (1)H-CSI may provide useful information for understanding the pathologic process underlying PC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proton chemical shift imaging in normal pressure hydrocephalus.

BACKGROUND AND PURPOSE Differentiation of normal pressure hydrocephalus (NPH) from other types of dementia and the selection of appropriate candidates for shunt surgery remain a clinical challenge. The aims of this study were to assess the efficacy of cerebral metabolites depicted by proton chemical shift imaging (1H-CSI) in distinguishing NPH from other dementias and to examine the relationshi...

متن کامل

TmDOTA-Tetraglycinate Encapsulated Liposomes as pH-Sensitive LipoCEST Agents

Lanthanide DOTA-tetraglycinate (LnDOTA-(gly)₄⁻) complexes contain four magnetically equivalent amide protons that exchange with protons of bulk water. The rate of this base catalyzed exchange process has been measured using chemical exchange saturation transfer (CEST) NMR techniques as a function of solution pH for various paramagnetic LnDOTA-(gly)₄⁻ complexes to evaluate the effects of lanthan...

متن کامل

Repeatability of two-dimensional chemical shift imaging multivoxel proton magnetic resonance spectroscopy for measuring human cerebral choline-containing compounds

AIM To investigate the repeatability of proton magnetic resonance spectroscopy in the in vivo measurement of human cerebral levels of choline-containing compounds (Cho). METHODS Two consecutive scans were carried out in six healthy resting subjects at a magnetic field strength of 1.5 T. On each occasion, neurospectroscopy data were collected from 64 voxels using the same 2D chemical shift ima...

متن کامل

Magnetic Resonance in Medicine

The chemical-shift effect often degrades slice selectivity thereby degrading the contrast and spatial resolutions in a high-field NMR imaging. We propose a new pulse sequence which can compensate for this chemical-shift effect during slice selection. This technique provides correct slice definition as well as clear separation between water and lipid protons in high-field proton NMR imaging. Par...

متن کامل

Multisection fat-water imaging with chemical shift selective presaturation.

Proton chemical shift imaging yielding separate water and lipid images was performed in a multisection mode on a clinical 1.5-T whole-body magnetic resonance imaging unit. Imaging was performed with a minor modification of the standard multisection spin-warp technique: that is, the addition of a sinc pulse or a soft square pulse and a homospoil gradient at the beginning of the pulse sequence. P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 23 8  شماره 

صفحات  -

تاریخ انتشار 2002