Infrared monitoring of expired carbon dioxide tension during anesthesia with and without nitrous oxide

نویسنده

  • RICHARD L. KEENAN
چکیده

Recently, the utilization of infrared analysis of expired gas to monitor end-tidal carbon dioxide partial pressure (PETCO 2 ) during anesthesia has gained in popularity. In contrast to arterial blood gas analysis, PETCO 2 analysis is immediate and continuous. Mass spectrometry has also been used to measure PETCO, and has been found to correlate well with arterial carbon dioxide partial pressure (PaCO,). 1 Other expired gases delivered during anesthesia, particularly nitrous oxide (N20), may affect the accuracy of infrared measurement. Because N2O is used as part of virtually every general anesthetic, it is of clinical importance to determine what effect it has on the value of infrared-determined PETCO2 relative to PaCO,. The study: methods Fifteen adult patients scheduled for routine nonthoracic surgical procedures gave their informed written consent for a study to determine the effects of N0O on infrared CO2 measurement. There were 10 males, aged 21 to 53 years (mean age 35), and 5 females, aged 30 to 47 years (mean age 36). All subjects were ASA physical status 1 or 2 and free of documented pulmonary disease. Following induction of general anesthesia and intubation, ventilation was either controlled or assisted. After isoflurane in 60% N,O and 40% oxygen was breathed from a partial rebreathing circle carbon dioxide absorption system (total flow 5 L/min) for no less than 30 minutes, a 3 ml heparinized blood sample was obtained anaerobically from the radial artery. Simultaneously, PETCO2 was measured with a Cavitron model PM20R infrared carbon dioxide analyzer. A single instrument was used for all studies. Details of calibration were as follows: After a 30 minute warm up period, the sampling flow was adjusted to 150 ml/min. "Zero" was set using ambient air. A calibrating gas consisting of 5.30% carbon dioxide, 12.63% oxygen and 82.07% nitrogen was then sampled and the span adjusted to 40 mmHg. A barometric pressure of 755 mmHg was assumed in all cases. Calibration and waveform signals were recorded in mmHg on a strip-

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of general anaesthesia on size of cerebrospinal fluid spaces during and after pneumoencephalography.

The mode of anaesthesia used during pneumoencephalography has a significant effect on the size of the cerebral ventricles 24 hours after the procedure. Post-encephalographic ventricular enlargement is less marked in patients examined under nitrous oxide anaesthesia. This appears to be related to passage of the gas into the ventricles during the encephalogram, and subsequent diffusion outwards. ...

متن کامل

The measurement of gaseous exchange during nitrous oxide anaesthesia.

A method is described for the estimation of carbon dioxide output, oxygen uptake, and respiratory exchange ratio during nitrous oxide anaesthesia. The inspired and expired minute volumes are measured with a box-bag system, the carbon dioxide concentrations with a carbon dioxide sensitive electrode, and the oxygen concentrations with a polarograph. Carbon dioxide output can be measured with a co...

متن کامل

The effect on respiratory mechanics when using a Jackson surgical table in the prone position during spinal surgery

BACKGROUND Respiratory dynamics may be monitored and evaluated indirectly by measuring the peak inspiratory pressure and plateau pressure. In this study, the respiratory dynamics of patients undergoing spinal surgery using a Jackson surgical table were observed with a device after converting their position from supine to prone. The effects of the dynamic compliance and airway resistance were ob...

متن کامل

A prospective study of changes in liver function after operation under two forms of general anaesthesia.

The liver function of 65 patients was studied before and after operation under general anaesthesia. The liver function test used was a modified bromsulphthalein (b.s.p.) test which provided quantitative values for several parameters of liver function. The effects of two types of general anaesthetic were compared. One anaesthetic technique involved the administration of halothane to the spontane...

متن کامل

The estimation of carbon dioxide concentration in the presence of nitrous oxide, using a Lloyd-Haldane apparatus.

A method of gas analysis is described for estimating carbon dioxide in the presence of nitrous oxide, using a modified Lloyd-Haldane apparatus. Some of the sample, after scrubbing with soda-lime, bubbles through the potash and this eliminates the solubility effect of nitrous oxide by equilibrating the standard potash solution with nitrous oxide at the tension of the sample analysed and eliminat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008