Off-frequency tuning error artifact in steady-state free precession cine imaging due to adjacent air-filled bowel.
نویسندگان
چکیده
Identification of common cardiovascular magnetic resonance (CMR) artifacts is important to optimal image acquisition quality and the avoidance of mistaken clinical diagnosis. We describe an off-frequency tuning error artifact observed during rapid steady-state free precession acquisitions in three patients and resulting in a dramatic appearance within the right and left ventricles. These artifacts were associated with large, adjacent air pockets within a loop of bowel or stomach and were eradicated by retuning of the magnetic resonance scanner's frequency. Awareness of this artifact, its cause and correction, should improve diagnostic image quality and avoid clinical diagnostic confusion. This report also heightens the need for a more robust shimming sequence for cardiac studies.
منابع مشابه
Banding Artifact Reduction in 2D CINE Balanced SSFP at 3.0 T Using Phase-Cycling and k-t BLAST
Introduction Balanced steady-state free precession (bSSFP) offers excellent signal-to-noise ratio (SNR) and consistent blood/myocardium contrast which renders 2D CINE bSSFP an ideal clinical choice for LV function assessment [1] at 1.5 T. bSSFP imaging remains challenging at 3.0 T due to its sensitivity to adverse off-resonance effects induced by strong field inhomogeneities at the heart-lung i...
متن کاملAcceleration of small bowel motility after oral administration of dai-kenchu-to (TJ-100) assessed by cine magnetic resonance imaging
Dai-kenchu-to (TJ-100) is an herbal medicine used to shorten the duration of intestinal transit by accelerating intestinal movement. However, intestinal movement in itself has not been evaluated in healthy volunteers using radiography, fluoroscopy, and radioisotopes because of exposure to ionizing radiation. The purpose of this study was to evaluate the effect of TJ-100 on intestinal motility u...
متن کاملComparison of breath hold and free breathing respiratory triggered retrospectively cardiac gated cine steady-state free precession (RT-SSFP) imaging in adults
Background The cine steady-state free-precession (SSFP) is the standard sequence for left ventricular (LV) function evaluation. However, SSFP mandates uninterrupted RF excitations to maintain steady-state (SS) during suspended respiration. In patients who cannot perform breath-holds (BH), a respiratory triggered (RT) free breathing (FB) retrospectively cardiac gated cine SSFP sequence that driv...
متن کاملClinical validation of free breathing Respiratory Triggered Retrospectively Cardiac Gated Cine Steady-State Free Precession (RT-SSFP) imaging in sedated children
Background Cine steady-state free precession (SSFP) is the preferred sequence for ventricular function evaluation. However, SSFP demands uninterrupted RF excitation to maintain steady-state (SS) during suspended respiration. This is feasible in adults who can perform breath-holding (BH), but is difficult to accomplish in sedated or uncooperative children. To overcome this, many pediatric groups...
متن کاملThrough-slice dephasing for eddy current artifact reduction in bSSFP
Eddy current effects can severely degrade image quality when using balanced steady-state free precession imaging with rapidly varying phase encode ordering schemes, which have common use in cardiac cine MRI. In this work, we explore and characterize a previouslyproposed technique, through-slice dephasing, as the sole technique for eddy current artifact removal. We demonstrate that artifacts var...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
دوره 6 3 شماره
صفحات -
تاریخ انتشار 2004