Quantification of septal and whole slice myocardial blood flow by myocardial perfusion CMR is similar in healthy volunteers

نویسندگان

  • Bara Erhayiem
  • Ananth Kidambi
  • David P Ripley
  • Adam K McDiarmid
  • Steven Sourbron
  • John P Greenwood
  • Sven Plein
چکیده

Background First pass myocardial perfusion CMR allows quantification of myocardial blood flow (MBF). MBF estimation with whole-heart tissue response may be useful in a variety of systemic diseases, but can be limited by suboptimal imaging in one or more segments. The interventricular septum (IVS) offers an attractive target for MBF imaging, as it offers higher signal and less partial volume artefact from blood pool. It has been proposed that T1 measurements taken from the IVS are more reliable than measurements from an entire short axis slice. We hypothesised that MBF estimation from the IVS would be similar to whole-heart estimation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility study

BACKGROUND In patients with ischemic heart disease, accurate assessment of the extent of myocardial perfusion deficit may be important in predicting prognosis of clinical cardiac outcomes. The aim of this study was to compare the ability of three dimensional (3D) and of two dimensional (2D) multi-slice myocardial perfusion imaging (MPI) using cardiovascular magnetic resonance (CMR) in determini...

متن کامل

Patients with syndrome X have normal transmural myocardial perfusion and oxygenation: a 3-T cardiovascular magnetic resonance imaging study.

BACKGROUND The pathophysiology of chest pain in patients with cardiac syndrome X remains controversial. Advances in perfusion imaging with cardiovascular magnetic resonance (CMR) now enable absolute quantification of regional myocardial blood flow (MBF). Furthermore, blood oxygen level-dependent (BOLD) or oxygenation-sensitive CMR provides the unprecedented capability to assess regional myocard...

متن کامل

Patients with Syndrome X have normal myocardial oxygenation and perfusion compared to normal volunteers: a 3 Tesla cardiovascular magnetic resonance imaging study

Introduction The pathophysiology of chest pain in patients with Syndrome X remains controversial. Previous studies using nuclear techniques or CMR to assess myocardial perfusion have shown conflicting results. Advances in perfusion imaging with CMR now enable absolute quantification of regional myocardial blood flow. Furthermore, blood oxygenation level-dependent (BOLD) CMR provides the unprece...

متن کامل

Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment

BACKGROUND Quantification of myocardial perfusion from first-pass cardiovascular magnetic resonance (CMR) images at high contrast agent (CA) dose requires separate acquisition of blood pool and myocardial tissue enhancement. In this study, a dual-sequence approach interleaving 2D imaging of the arterial input function with high-resolution 3D imaging for myocardial perfusion assessment is presen...

متن کامل

Fully automated pixel-wise myocardial blood flow quantification with first-pass perfusion CMR

Methods Rest and adenosine stress perfusion imaging was performed on 17 normal volunteers. A saturation recovery SSFP dual-sequence technique was used to acquire three myocardial slices and an arterial input function (AIF) image series. A proton-density weighted image was acquired at the beginning of each series. Fully quantitative perfusion pixel maps were generated by an automated processing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014