Contrast sensitivity of the human pattern electroretinogram.
نویسندگان
چکیده
Contrast thresholds for the pattern electroretinogram (PERG) were measured using lock-in amplifier retrieval of the retinal signal and a swept contrast display. Contrast sensitivity functions (CSF) developed from these PERG contrast thresholds were compared with those established psychophysically under identical stimulus conditions. Whereas the PERG CSF showed a band-pass characteristic across temporal frequency, the psychophysical CSF (and a temporal CSF developed from visual evoked potential contrast thresholds) had a low-pass pattern. Across spatial frequency, the PERG and psychophysical CSFs had similar shapes, although the PERG CSF peaked at a lower spatial frequency than the psychophysical CSF.
منابع مشابه
Pattern electroretinogram and peripheral colour contrast thresholds in ocular hypertension and glaucoma: comparison and correlation of results.
AIMS Both pattern electroretinogram and peripheral colour contrast thresholds have been shown to be abnormal in glaucoma and ocular hypertension. This study evaluates each of these tests as tools for the early diagnosis of glaucoma, compares and contrasts the results, and examines the relation between the two tests in a large cohort of ocular hypertensive patients. METHODS Transient and stead...
متن کاملEffects of Ageing on Spatial Aspects of the Pattern Electroretinogram in Male and Female Quail
This study deals with age-related functional changes in the eye of quail. Measurements of lens refractive state and transmission, as well as pupil diameter, showed that the quail's eye became more myopic with increasing age, but no change could be detected in lens transmission and pupil diameter. Three aspects of the pattern electroretinogram (PERG) were studied after correcting for ocular refr...
متن کاملSpatial contrast transfer functions of the pattern-evoked electroretinogram.
Pattern ERGs in response to pattern-reversal stimuli varying in spatial frequency (range: 0.2-9.03 cycles/deg) and contrast (range: 0.03-0.93) were recorded from two normal male subjects. At most spatial frequencies the response amplitude increased linearly up to the highest contrast without saturation. From the amplitude-versus-contrast plots spatial contrast-transfer functions were derived fo...
متن کاملThe effect of background spatial contrast on electroretinographic responses in the human retina
The electroretinogram (ERG) was obtained to contrast modulation (CM). This stimulus is a product of temporal modulation of the contrast of a spatial sinusoid at constant mean luminance. Mean contrast (10-40%), and modulation depth (25-1.0) were modulated at 7.5Hz to record the pattern electroretinogram (PERG). The spatial pattern was a foveally fixated grating pattern with sinusoidal luminance ...
متن کاملHemifield pattern electroretinogram in ocular hypertension: comparison with frequency doubling technology and optical coherence tomography to detect early optic neuropathy
BACKGROUND To assess the sensitivity and specificity of hemifield pattern electroretinogram (HF-PERG) for detecting early retinal ganglion cell (RGC) damage in ocular hypertensive (OH) patients. METHODS Fifty-two OH patients (mean age 56±9.6 years) with an intraocular pressure (IOP) .21 mmHg were assessed. All subjects underwent HF-PERG, optical coherence tomography (OCT), and frequency doubl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 28 1 شماره
صفحات -
تاریخ انتشار 1987