Seminal vesicle interfraction displacement and margins in image guided radiotherapy for prostate cancer

نویسندگان

  • Daisy Mak
  • Suki Gill
  • Roxby Paul
  • Alison Stillie
  • Annette Haworth
  • Tomas Kron
  • Jim Cramb
  • Kellie Knight
  • Jessica Thomas
  • Gillian Duchesne
  • Farshad Foroudi
چکیده

BACKGROUND To analyze interfraction motion of seminal vesicles (SV), and its motion relative to rectal and bladder filling. METHODS AND MATERIALS SV and prostate were contoured on 771 daily computed tomography "on rails" scans from 24 prostate cancer patients undergoing radiotherapy. Random and systematic errors for SV centroid displacement were measured relative to the prostate centroid. Margins required for complete geometric coverage of SV were determined using isotropic expansion of reference contours. SV motion relative to rectum and bladder was determined. RESULTS Systematic error for the SV was 1.9 mm left-right (LR), 2.9 mm anterior-posterior (AP) and 3.6 mm superior-inferior (SI). Random error was 1.4 mm (LR), 2.7 mm (AP) and 2.1 mm (SI). 10 mm margins covered the entire left SV and right SV on at least 90% of fractions in 50% and 33% of patients and 15 mm margins covered 88% and 79% respectively. SV AP movement correlated with movement of the most posterior point of the bladder (mean R2 = 0.46, SD = 0.24) and rectal area (mean R2 = 0.38, SD = 0.21). CONCLUSIONS Considerable interfraction displacement of SV was observed in this cohort of patients. Bladder and rectal parameters correlated with SV movement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interfraction Prostate Movement in Bone Alignment After Rectal Enema for Radiotherapy

PURPOSE To assess the effect of a rectal enema on interfraction prostate movement in bone alignment (BA) for prostate radiotherapy (RT), we analyzed the spatial difference in prostates in a bone-matched setup. MATERIALS AND METHODS We performed BA retrospectively with data from prostate cancer patients who underwent image-guided RT (IGRT). The prostate was identified with implanted fiducial m...

متن کامل

Appropriate patient instructions can reduce prostate motion

BACKGROUND Interfraction prostate motion must be compensated by increased safety margins. If filling status of rectum and bladder is constant, motion should be reduced. We attempted to reduce interfraction motion errors by proper patient instruction. METHOD In 38 patients pairs of radio-opaque fiducial markers were implanted prior to definitive radiotherapy. Patients were positioned either ac...

متن کامل

[Quantification of the volumetric benefit of image-guided radiotherapy (IGRT) in prostate cancer: margins and presence probability map].

PURPOSE To quantify the prostate and seminal vesicles (SV) anatomic variations in order to choose appropriate margins including intrapelvic anatomic variations. To quantify volumetric benefit of image-guided radiotherapy (IGRT). PATIENTS AND METHODS Twenty patients, receiving a total dose of 70 Gy in the prostate, had a planning CT scan and eight weekly CT scans during treatment. Prostate and...

متن کامل

A cone beam CT-Based Study for Clinical Target Definition Using Pelvic Anatomy During Postprostatectomy Radiotherapy.

PURPOSE There are no accepted guidelines for target volume definition for online image-guided radiation therapy (IGRT) after radical prostatectomy (RP). This study used cone beam CT (CBCT) imaging to generate information for use in post-RP IGRT. METHODS AND MATERIALS The pelvic anatomy of 10 prostate cancer patients undergoing post-RP radiation therapy (RT) to 68.4 Gy was studied using CBCT i...

متن کامل

Inter- and intrafraction uncertainty in prostate bed image-guided radiotherapy.

PURPOSE The goals of this study were to measure inter- and intrafraction setup error and prostate bed motion (PBM) in patients undergoing post-prostatectomy image-guided radiotherapy (IGRT) and to propose appropriate population-based three-dimensional clinical target volume to planning target volume (CTV-PTV) margins in both non-IGRT and IGRT scenarios. METHODS AND MATERIALS In this prospecti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012