Reconstruction of Saccular and Dissected Intracranial Aneurysms Using Solitaire™ AB Stents

نویسندگان

  • Kai-Jun Zhao
  • Yong-Wei Zhang
  • Yi Xu
  • Bo Hong
  • Qing-Hai Huang
  • Wen-Yuan Zhao
  • Peng-Fei Yang
  • Jian-Min Liu
چکیده

INTRODUCTION We aimed to evaluate the feasibility, safety, efficacy, and predictors for outcome of reconstructive treatment with Solitaire™ AB stent(s) based on 54 cases of saccular aneurysms and 14 of acute symptomatic dissecting aneurysms. METHODS Fifty-eight consecutive patients (M/F = 28/30; median age, 53 years) harbouring 68 aneurysms (ruptured/unruptured = 12/56) underwent treatment with Solitaire™ AB stent(s) implantation between April 2010 and August 2011 in our institution. The data were retrospectively reviewed and analysed. RESULTS The technical success rate of Solitaire™ AB stenting was 100%. The rates of the overall and the treatment-related adverse events were 9% (6/68) and 6% (4/68), respectively, and the recurrent rate was 1% (1/68). All of the adverse events (n = 6) occurred in tiny (n = 1, ≤3 mm) or small (n = 5, >3 to ≤10 mm) aneurysms. The majority (75%, 3/4) of thromboembolic events (thrombus, n = 2; infarction, n = 2) occurred in ruptured lesions, and 2 intraprocedural aneurysm ruptures occurred in the course of coiling when the stent(s) was/were applied within 6 months. Subarachnoid haemorrhages (SAH, p<0.05) and immediate occlusion grades (p<0.05) were predictors for overall adverse events by univariate analysis. Compared with the immediate post-treatment angiographic results, the follow-up angiographic imaging (mean, 13 months; range, 6-25 months) revealed that stent(s) implantation enhanced the rate of class I occlusion from 34% (23/68) to 93% (63/68). SAH was the only predictor for unfavourable outcomes (the modified Rankin Scale score [mRS], 2-6) during the mean 19-month (range, 12-27 months) of clinical follow-ups (p<0.05). CONCLUSIONS Although the complete obliteration of tiny and small aneurysms without complications remains a challenge, stent(s) implantation could lead to further occlusion of incompletely coiled aneurysms. SAH and the occlusion grade were the primary predictors for adverse events. SAH was the only predictor for unfavourable outcomes by univariate analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical and Angiographic Outcomes of Wide-necked Aneurysms Treated with the Solitaire AB Stent

OBJECTIVE This study investigated the clinical and angiographic outcomes of treatment with stent-assisted coil embolization using the Solitaire AB stents for wide-necked intracranial aneurysms. METHODS From October 2010 to December 2011, 22 patients with aneurysms were treated with the Solitaire AB stent. One patient with a dissecting aneurysm was excluded, thus 21 patients with 21 wide-necke...

متن کامل

Clinical application of solitaire AB stents in the embolization of intracranial aneurysms.

OBJECTIVE To evaluate the clinical value of Solitaire AB stents in the embolization of intracranial aneurysms. PATIENTS AND METHODS Solitaire AB stents were applied in treating 69 aneurysms in 65 patients. Among them, there were 67 "wide neck" aneurysms and two "narrow neck" aneurysms. Of the 69 aneurysms, there were 40 aneurysms in the posterior communicating artery, 13 in the ophthalmic art...

متن کامل

Solitaire AB Stent-Assisted Coiling of Wide-Neck Micro Aneurysms

OBJECTIVE Solitaire AB stent-assisted coiling facilitates the endovascular treatment of wide-necked intracranial aneurysms. We present our experience of coiling the micro-aneurysms of wide-neck with Solitaire AB stent assisting in a single center. METHODS Thirty-one Solitaire AB stents were used to treat via endovascular approach patients with 31 wide-neck micro aneurysms in a single center i...

متن کامل

The Use of Solitaire AB Stents in Coil Embolization of Wide-Necked Cerebral Aneurysms

BACKGROUND The Solitaire AB stent is one of many assistant stents used for treating wide-necked cerebral aneurysm, and has been used since 2003. However, large sample studies on its safety and effectiveness are lacking. The objective of this study was to evaluate the effectiveness and safety of the Solitaire AB stent in the coil embolization of wide-necked cerebral aneurysms. METHODS Retrospe...

متن کامل

Outcomes of Stent-assisted Coil Embolization of Wide-necked Intracranial Aneurysms Using the Solitaire™ AB Neurovascular Remodeling Device

OBJECTIVE This retrospective study presents our experience with respect to the clinical and angiographic outcomes of patients treated with stent-assisted coil embolization using Solitaire™ AB stents. MATERIALS AND METHODS From March 2011 to December 2014, 50 patients with 55 wide-necked and/or complex intracranial aneurysms were evaluated. Four patients presented with an acute subarachnoid he...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013