Epidemiologic studies have demonstrated a consistent link between sudden cardiac deaths and particulate air pollution. We used implanted cardioverter defibrillator (ICD) records of ventricular tachyarrhythmias to assess the role of air pollution as a trigger of these potentially life-threatening events. The study cohort consisted of 203 cardiac patients with ICD devices in the Boston metropolitan area who were followed for an average of 3.1 years between 1995 and 2002. Fine particle mass and gaseous air pollution plus temperature and relative humidity were measured on almost all days, and black carbon, sulfate, and particle number on a subset of days. Date, time, and intracardiac electrograms of ICD-detected arrhythmias were downloaded at the patients' regular follow-up visits (about every 3 months). Ventricular tachyarrhythmias were identified by electrophysiologist review. Risk of ventricular arrhythmias associated with air pollution was estimated with logistic regression, adjusting for season, temperature, relative humidity, day of the week, patient, and a recent prior arrhythmia. We found increased risks of ventricular arrhythmias associated with 2-day mean exposure for all air pollutants considered, although these associations were not statistically significant. We found statistically significant associations between air pollution and ventricular arrhythmias for episodes within 3 days of a previous arrhythmia. The associations of ventricular tachyarrhythmias with fine particle mass, carbon monoxide, nitrogen dioxide, and black carbon suggest a link with motor vehicle pollutants. The associations with sulfate suggest a link with stationary fossil fuel combustion sources.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increased Risk of Paroxysmal Atrial Fibrillation Episodes Associated with Acute Increases in Ambient Air Pollution

OBJECTIVES We reported previously that 24-hr moving average ambient air pollution concentrations were positively associated with ventricular arrhythmias detected by implantable cardioverter defibrillators (ICDs). ICDs also detect paroxysmal atrial fibrillation episodes (PAF) that result in rapid ventricular rates. In this same cohort of ICD patients, we assessed the association between ambient ...

متن کامل

Association of short-term ambient air pollution concentrations and ventricular arrhythmias.

The authors evaluated the association between ventricular arrhythmias detected by implantable cardioverter defibrillators and ambient air pollution concentrations in the hours immediately before the arrhythmia. Patients given implantable cardioverter defibrillators at the New England Medical Center in Boston, Massachusetts, between mid-1995 and 1999 who lived within 40 km of a central monitorin...

متن کامل

Association of ventricular arrhythmias detected by implantable cardioverter defibrillator and ambient air pollutants in the St Louis, Missouri metropolitan area.

BACKGROUND It has previously been reported that the risk of ventricular arrhythmias is positively associated with ambient air pollution among patients with implantable cardioverter defibrillators (ICD) in Boston. AIMS To assess the association of community exposures to air pollution with ventricular arrhythmias in a cohort of ICD patients in metropolitan St Louis, Missouri. METHODS ICD dete...

متن کامل

Proarrhythmic effect of pacemaker stimulation in patients with implanted cardioverter-defibrillators.

BACKGROUND We sought to determine the potential of right ventricular VVI backup pacing to induce ventricular tachyarrhythmias in patients with implanted cardioverter-defibrillators. METHODS AND RESULTS All consecutive patients presenting exclusively with pacemaker-induced tachycardias (PITs) were included in a prospective study using a crossover protocol. Patients were randomized to either gr...

متن کامل

Tachycardia induction due to inappropriate implantable cardioverter defibrillator therapy: what is the mechanism?

Antitachycardia therapies administered by implantable cardioverter defibrillators (ICDs) can occasionally prove proarrhythmic due to induction of ventricular tachyarrhythmias. In this report we present the case of a tachycardia induction as a result of inappropriate therapy delivery in an ICD recipient. Detailed analysis of the stored electrograms facilitated the delineation of the underlying m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 113  شماره 

صفحات  -

تاریخ انتشار 2005