Comparative Study between Sequential Automatic and Manual Home Respiratory Polygraphy Scoring Using a Three-Channel Device: Impact of the Manual Editing of Events to Identify Severe Obstructive Sleep Apnea

نویسندگان

  • Glenda Ernst
  • Martín Bosio
  • Alejandro Salvado
  • Facundo Nogueira
  • Carlos Nigro
  • Eduardo Borsini
چکیده

Objective. According to current guidelines, autoscoring of respiratory events in respiratory polygraphy requires manual scoring. The aim of this study was to evaluate the agreement between automatic analysis and manual scoring to identify patients with suspected OSA. Methods. This retrospective study analyzed 791 records from respiratory polygraphy (RP) performed at home. The association grade between automatic scoring and manual scoring was evaluated using Kappa coefficient and the agreement using Bland and Altman test and intraclass correlation coefficient (CCI). To determine the accuracy in the identification of AHI ≥ 30 eV/h, the ROC curve analysis was used. Results. The population analyzed consisted of 493 male (62.3%) and 298 female patients, with an average age of 54.7 ± 14.20 years and BMI of 32.7 ± 8.21 kg/m(2). There was no significant difference between automatic and manual apnea/hypopnea indexes (aAHI, mAHI): aAHI 17.25 (SD: 17.42) versus mAHI 21.20 ± 7.96 (p; NS). The agreement between mAHI and aAHI to AHI ≥ 30 was 94%, with a Kappa coefficient of 0.83 (p < 0.001) and a CCI of 0.83. The AUC-ROC, sensitivity, and specificity were 0.99 (CI 95%: 0.98-0.99, p < 0.001), 86% (CI 95%: 78.7-91.4), and 97% (CI 95%: 96-98.3), respectively. Conclusions. We observed good agreement between automatic scoring and sequential manual scoring to identify subjects with AHI ≥ 30 eV/h.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of sequential automatic-manual home respiratory polygraphy scoring.

Automatic home respiratory polygraphy (HRP) scoring functions can potentially confirm the diagnosis of sleep apnoea-hypopnoea syndrome (SAHS) (obviating technician scoring) in a substantial number of patients. The result would have important management and cost implications. The aim of this study was to determine the diagnostic cost-effectiveness of a sequential HRP scoring protocol (automatic ...

متن کامل

Comparison of a cardiorespiratory device versus polysomnography for diagnosis of sleep apnoea.

This study assessed the accuracy of a cardiorespiratory monitoring device versus polysomnography for the diagnosis of suspected sleep apnoea/hypoponea syndrome (SAS). A total of 86 patients (89% male, mean age 52 yrs) that had been referred to a sleep laboratory with a clinical diagnosis of SAS underwent cardiorespiratory polygraphy in an unattended mode using an ambulatory device (MERLIN). Ana...

متن کامل

Evaluation of the accuracy of manual and automatic scoring of a single airflow channel in patients with a high probability of obstructive sleep apnea

BACKGROUND ApneaLink (AL) is a single-channel type-4 device that measures airflow. A limited number of studies have assessed AL's usefulness in diagnosing obstructive sleep apnea (OSA) using automated scoring alone. This study was conducted to assess the sensitivity and specificity of AL in a selected group of people with clinical suspicion of OSA, using both automatic and manual scoring and co...

متن کامل

[Validation of a respiratory polygraphy system in the diagnosis of sleep apnea syndrome].

OBJECTIVE To validate a cardiorespiratory polygraphy system (BITMED NGP 140) by comparing it to conventional polysomnography in the diagnosis of sleep apnea-hypopnea syndrome. PATIENTS AND METHODS Polysomnography and cardio-respiratory polygraphy were performed simultaneously on 103 consecutive patients referred because of suspected sleep apnea-hypopnea syndrome. The Bland and Altman method a...

متن کامل

Effects of Biofeedback Therapy on Cardiovascular and Respiratory Indices in NREM Sleep Parasomnias with Obstructive Sleep Apnea: A Case study

Introduction: Non-REM parasomnias are a relatively common condition in the general human population. Current treatment plans are usually based on small case series and reports. Considering the effects of sleep disorders on different aspects of human life and the failure of pharmacological treatments in this field, the present study was designed to investigate a case of this sleep disorders with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015