Fivefold reduction in peritonitis using a multifaceted continuous quality initiative program.
نویسندگان
چکیده
Despite recent advances in peritoneal dialysis (PD) systems, peritonitis is a significant clinical problem in patients on PD. Risk factors for peritonitis are identifiable and modifiable and require focused intervention. During a baseline period in 1998, we observed consistent differences in peritonitis rates among patients using various PD connection systems. In January 1999, motivated by a need to reduce peritonitis, we initiated a multifaceted continuous quality initiative (CQI) program that included retraining all current patients and all new patients 6 months after initiation and then annually; changing from plastic to titanium adapters between the catheter and the transfer set; and using equipment from a single PD manufacturer for all new patients and for current patients with high peritonitis rates. Furthermore, all patients using HomeChoice cyclers (Baxter Healthcare Corporation, McGaw Park, IL, U.S.A.) were taught to use the Compact Exchange Device II to avoid contamination when spiking solution bags. Peritonitis rates improved from 1 episode per 7.5 patient-months (over 512 patient-months) in 1998 to 1 episode per 36.5 patient-months (over 292 patient-months) as of September 2002. Further analysis also showed a significant difference in peritonitis rates between equipment produced by various manufacturers. There was a statistically significant difference in peritonitis for automated peritoneal dialysis systems. Patients using the Freedom Cycler PD+ (Fresenius Medical Care, Frankfurt, Germany) had an average peritonitis rate of 1 episode per 6.9 patient-months as compared with patients using the HomeChoice cycler (Baxter Healthcare), who experienced 1 episode of peritonitis per 23.9 patient-months on average (p < 0.0001). For continuous ambulatory peritoneal dialysis patients using UltraBag (Baxter Healthcare), the peritonitis rate was 1 episode per 26 patient-months as compared with the Premier Double Bag (Fresenius Medical Care), for which a peritonitis rate of 1 episode per 6.3 patient-months was seen (p < 0.0001). Comparison of the UltraBag (1 episode per 26.0 patient-months) with the Disposable Freedom Set, a single-bag "Y" system (Fresenius Medical Care; 1 episode per 7.5 patient-months) yielded similar results (p < 0.0001). We conclude that ongoing CQI efforts can significantly reduce peritonitis rates. Our efforts included aggressive patient retraining, protocol changes, use of a titanium adapter between the catheter and the transfer set, and careful choice of connectology systems (possible supplier-dependent effect).
منابع مشابه
Rates of continuous ambulatory peritoneal dialysis-associated peritonitis at the University of Missouri.
Peritoneal dialysis (PD)-associated peritonitis contributes significantly to morbidity and modalityfailure. The number of patients on PD is declining in Western countries, and peritonitis is a potential deterrent to the therapy. Here, we present a clinically significant decline in the rate of peritonitis at a single center over a 28-year period, with current rates significantly lower than the n...
متن کاملMaintaining Information Security during Downsizing
Today, companies of every size are relying on Internet and other network connections to support their business. For each of those businesses, information and network security have become increasingly important. Yet, achieving a security level that will adequately protect a business is a difficult task because information security is a multifaceted undertaking. A successful information security ...
متن کاملExamining the Effectiveness of Mindfulness-based Stress Reduction Program and Conscious Yoga on Quality of Life in Patients with Diabetes Type 2
Objective: Diabetes is a chronic disease that causes severe side effects in patients. According to the previous studies, the incidence of depression and anxiety is higher among patients with diabetes type 2. The present study was conducted with the aim of examining the effectiveness of mindfulness-based stress reduction program and conscious yoga on depression, anxiety and stress in patients wi...
متن کاملA Review the Role of Midwife-led Care Model in Managing the Costs of Healthy Reproductive Services
Objective: For improving the quality of reproductive health services and providing appropriate health care to mothers to reduce their mortality and morbidity, it requires to apply the effective cost models used in the world. In this regard, the aim of the current study is to critically review the related literature on cost management of healthy reproductive services with the continuous midwifer...
متن کاملClinical outcomes in peritoneal dialysis: impact of continuous quality provement initiatives.
The Kidney Disease Outcomes Quality Initiative guidelines for peritoneal dialysis (PD) emphasize the need for quality improvement interventions to improve outcomes in PD. Here, we report 17 years experience of initiatives focused on lowering peritonitis rates in a single PD program. This institutional review board-approved retrospective analysis used a PD registry containing prospectively colle...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Advances in peritoneal dialysis. Conference on Peritoneal Dialysis
دوره 19 شماره
صفحات -
تاریخ انتشار 2003