Dose-response curve of a microfluidic magnetic bead-based surface coverage sandwich assay.

نویسندگان

  • Matteo Cornaglia
  • Raphaël Trouillon
  • H Cumhur Tekin
  • Thomas Lehnert
  • Martin A M Gijs
چکیده

Magnetic micro- and nanoparticles ('magnetic beads') have been used to advantage in many microfluidic devices for sensitive antigen (Ag) detection. Today, assays that use as read-out of the signal the number count of immobilized beads on a surface for quantification of a sample's analyte concentration have been among the most sensitive and have allowed protein detection lower than the fgmL(-1) concentration range. Recently, we have proposed in this category a magnetic bead surface coverage assay (Tekin et al., 2013 [1]), in which 'large' (2.8μm) antibody (Ab)-functionalized magnetic beads captured their Ag from a serum and these Ag-carrying beads were subsequently exposed to a surface pattern of fixed 'small' (1.0μm) Ab-coated magnetic beads. When the system was exposed to a magnetic induction field, the magnet dipole attractive interactions between the two bead types were used as a handle to approach both bead surfaces and assist with Ag-Ab immunocomplex formation, while unspecific binding (in absence of an Ag) of a large bead was reduced by exploiting viscous drag flow. The dose-response curve of this type of assay had two remarkable features: (i) its ability to detect an output signal (i.e. bead number count) for very low Ag concentrations, and (ii) an output signal of the assay that was non-linear with respect to Ag concentration. We explain here the observed dose-response curves and show that the type of interactions and the concept of our assay are in favour of detecting the lowest analyte concentrations (where typically either zero or one Ag is carried per large bead), while higher concentrations are less efficiently detected. We propose a random walk process for the Ag-carrying bead over the magnetic landscape of small beads and this model description explains the enhanced overall capture probability of this assay and its particular non-linear dose response curves.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A double-bead sandwich assay for protein detection in serum based on Localized Surface Plasmon Resonance

In this study, the importance of pre-concentration is clearly demonstrated for the covalent immobilization of various proteins to magnetic nanoparticles through mild carbodiimide activation. Additionally, the covalently biofunctionalized magnetic nanoparticles are employed in a double-bead sandwich assay, using gold nanoparticles. The magnetic nanoparticles allow specific capturing of the analy...

متن کامل

Heterogeneous immunoassays using magnetic beads on a digital microfluidic platform.

A digital microfluidic platform for performing heterogeneous sandwich immunoassays based on efficient handling of magnetic beads is presented in this paper. This approach is based on manipulation of discrete droplets of samples and reagents using electrowetting without the need for channels where the droplets are free to move laterally. Droplet-based manipulation of magnetic beads therefore doe...

متن کامل

Attomolar protein detection using a magnetic bead surface coverage assay.

We demonstrate a microfluidic method for ultra-sensitive protein detection in serum. First, 'large' (2.8 μm) antibody-functionalized magnetic beads specifically capture antigen from a serum matrix under active microfluidic mixing. Subsequently, the large beads loaded with the antigens are gently exposed to a surface pattern of fixed 'small' (1.0 μm) antibody-coated magnetic beads. During the ex...

متن کامل

Label-acquired magnetorotation for biosensing: An asynchronous rotation assay.

This paper presents a novel application of magnetic particles for biosensing, called label-acquired magnetorotation (LAM). This method is based on a combination of the traditional sandwich assay format with the asynchronous magnetic bead rotation (AMBR) method. In label-acquired magnetorotation, an analyte facilitates the binding of a magnetic label bead to a nonmagnetic solid phase sphere, for...

متن کامل

A magnetic bead-based assay for the rapid detection of methicillin-resistant Staphylococcus aureus by using a microfluidic system with integrated loop-mediated isothermal amplification.

This study reports a new diagnostic assay for the rapid detection of methicillin-resistant Staphylococcus aureus (MRSA) by combing nucleic acid extraction and isothermal amplification of target nucleic acids in a magnetic bead-based microfluidic system. By using specific probe-conjugated magnetic beads, the target deoxyribonucleic acid (DNA) of the MRSA can be specifically recognized and hybrid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • New biotechnology

دوره 32 5  شماره 

صفحات  -

تاریخ انتشار 2015