Theory of a Double-diaphragm Mems Ultrasonic Transducer
نویسنده
چکیده
Conventional capacitive MEMS transducer designs feature a single flexible diaphragm acting as a moving plate and an electrode patterned on the substrate acting as a stationary plate. Such devices generally function adequately as receivers. However, such devices show poor transmission efficiency when the gap dimension is limited by the manufacturing process and when the diaphragm would suffer “pull-in” collapse if deflected electrostatically beyond a critical fraction of the gap dimension. We describe a novel design, one that can be easily fabricated within an existing multi-layer polysilicon process, to achieve more efficient emission. The design features two flexible diaphragms to be actuated by a coordinated series of pulses. We report predictions of the improvement using dimensions characteristic of a multi-user surface-machined MEMS process.
منابع مشابه
Mems Phased Array Detection in Contact with Solids
We report on the development of transducers for ultrasonic flaw detection which can be permanently mounted at critical locations on structures. We will show that MEMS capacitive diaphragm transducers can be bonded to metal or plexiglas test speciments without damage and that ultrasonic energy can be efficiently coupled into the transducer. It will be demonstrated that transducer arrays can be o...
متن کاملA MEMS Transducer for Ultrasonic Flaw Detection
Metal structures can fail because of fatigue crack propagation or because of section loss from corrosion. Regular inspection is required to intercept such failures, and in situ sensors would be a superior technology for that purpose. We have designed and fabricated arrays of MEMS capacitive diaphragm transducers and we report on their performance as pulse-echo detectors in direct contact with s...
متن کاملSimulation and Derivation of Deflection Equation for Suspended Diaphragm for MEMS Application Using Kirchhoff-Love Theory
In this paper, using theory of sheets, the deflection of suspended diaphragm has been obtained under uniform and circular loading. This type of diaphragm, unlike other diaphragms, has a central support which is recommended to be used in MEMS applications. The relationship between diaphragm deflection and static analysis of this diaphragm enjoys a great significance in investigating and understa...
متن کاملThe Effect of Corrugations on Mechanical Sensitivity of Diaphragm for MEMS Capacitive Microphone
In this paper the effect of corrugated diaphragm on performance of MEMS microphone is described. The corrugated diaphragm is modeled in order to improve the sensitivity of micromachined silicon acoustic sensor. Analytical analyzes have been carried out to derive mathematic expressions for the mechanical sensitivity and displacement of corrugated diaphragm with residual stress. It is shown that ...
متن کاملSubmitted for “Identification of Existing and Emerging Microelectromechanical Systems (MEMS) Applications” session, sponsored by committee A2F09 Design and Testing of a MEMS Ultrasonic Transducer for Flaw Detection
Ultrasonic pulse-echo methods are versatile, effective procedures for inspecting welds in steel structures. However, the ultrasonic methods conventionally used have two disadvantages: inspection must be performed manually by a skilled technician, and the signal obtained at the time of one inspection provides no “memory” to be used at the time of a later inspection. Our research involves the dev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004