Percutaneous extracorporeal arteriovenous carbon dioxide removal improves survival in respiratory distress syndrome: a prospective randomized outcomes study in adult sheep.
نویسندگان
چکیده
OBJECTIVE Arteriovenous carbon dioxide removal (AVCO(2)R) uses a simple arteriovenous shunt for CO(2) removal to minimize barotrauma/volutrauma from mechanical ventilation. We performed a prospective randomized outcomes study of AVCO(2)R in our new, clinically relevant model of respiratory distress syndrome. METHODS Adult sheep (n = 18) received an LD(50) severe smoke inhalation and 40% third-degree burn. When respiratory distress syndrome developed (PaO (2)/FIO (2) < 200 at 40 to 48 hours), animals were randomized to the AVCO(2)R (n = 9) or sham group (n = 9) for 7 days. Ventilator management protocols mandated reductions in minute ventilation, first tidal volume to peak inspiratory pressure less than 30 cm H(2)O, then respiratory rate when PaCO (2) was less than 40 mm Hg. PaO (2) was kept above 60 mm Hg by adjusting FIO (2). When FIO (2) was 0.21, animals were weaned. RESULTS The study required 2946 animal-hours of critical care with 696 AVCO(2)R hours. One died in each group during model development. AVCO(2)R flow from 820 mL/min to 970 mL/min (11% to 14% cardiac output) removed CO(2) at a rate of 92 to 116 mL/min (mean 103 mL/min; 93%-97% of CO(2) production). Heart rate, mean arterial pressure, cardiac output, and pulmonary arterial wedge pressure remained relatively constant. Within 48 hours, AVCO(2)R allowed significant ventilator reductions versus baseline in the following measurements: tidal volume (420 to 270 mL), peak inspiratory pressure (25 to 14 cm H(2)O), minute ventilation (13 to 5 L/min), respiratory rate (26 to 16 breaths/min), and FIO (2) (0.88 to 0.35). Ventilator-free days with AVCO(2)R were 3.9 versus 0.2 (P <.01) for sham animals, and ventilator-dependent days with AVCO(2)R were 2.4 versus 6.2 (P <.01) for the 3 sham survivors. All 8 AVCO(2)R animals and 3 of 8 sham animals survived 7 days after randomization. CONCLUSIONS Percutaneous AVCO(2)R achieved significant reduction in airway pressures, increased ventilator-free days, decreased ventilator-dependent days, and improved survival in a sheep model of respiratory distress syndrome.
منابع مشابه
Carbon dioxide removal device: how long is long enough?
In 1969 Kolobow and coworkers [2] described use of VVCO2R in healthy sheep for 1 week, and they later demonstrated improved survival in injured sheep [3]. Clinical trials, however, failed to show improved outcomes [4]. Arteriovenous carbon dioxide removal (AVCO2R), as a simple arteriovenous shunt, eliminates several circuit components. AVCO2R removes near total carbon dioxide production with on...
متن کاملExtracorporeal gas exchange and spontaneous breathing for the treatment of acute respiratory distress syndrome: an alternative to mechanical ventilation?*.
OBJECTIVES Venovenous extracorporeal gas exchange is increasingly used in awake, spontaneously breathing patients as a bridge to lung transplantation. Limited data are available on a similar use of extracorporeal gas exchange in patients with acute respiratory distress syndrome. The aim of this study was to investigate the use of extracorporeal gas exchange in awake, spontaneously breathing she...
متن کاملRandomized clinical trial of pressure-controlled inverse ratio ventilation and extracorporeal CO2 removal for adult respiratory distress syndrome.
The impact of a new therapy that includes pressure-controlled inverse ratio ventilation followed by extracorporeal CO2 removal on the survival of patients with severe ARDS was evaluated in a randomized controlled clinical trial. Computerized protocols generated around-the-clock instructions for management of arterial oxygenation to assure equivalent intensity of care for patients randomized to ...
متن کاملPumpless extracorporeal interventional lung assist in patients with acute respiratory distress syndrome: a prospective pilot study
INTRODUCTION Pumpless interventional lung assist (iLA) is used in patients with acute respiratory distress syndrome (ARDS) aimed at improving extracorporeal gas exchange with a membrane integrated in a passive arteriovenous shunt. In previous studies, feasibility and safety of the iLA system was demonstrated, but no survival benefit was observed. In the present pilot study we tested the hypothe...
متن کاملExtracorporeal carbon dioxide removal for patients with acute respiratory failure secondary to the acute respiratory distress syndrome: a systematic review
Acute respiratory distress syndrome (ARDS) continues to have significant mortality and morbidity. The only intervention proven to reduce mortality is the use of lung-protective mechanical ventilation strategies, although such a strategy may lead to problematic hypercapnia. Extracorporeal carbon dioxide removal (ECCO₂R) devices allow uncoupling of ventilation from oxygenation, thereby removing c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of thoracic and cardiovascular surgery
دوره 121 3 شماره
صفحات -