Protein microcrystal diffraction and the effects of radiation damage with ultra-high-flux synchrotron radiation.

نویسندگان

  • B Hedman
  • K O Hodgson
  • J R Helliwell
  • R Liddington
  • M Z Papiz
چکیده

By using ultra-high-flux synchrotron x-radiation from a wiggler source, good Laue diffraction data have been obtained from protein microcrystals of size 30 X 35 X 10 microns3, mounted wet in glass capillaries. At the flux level of 10(13)-10(14) photons per sec/mm2, the radiation damage is still low enough to allow a large survey of reciprocal space for a microcrystal and a complete survey for a normal-sized protein crystal. The development of sources for ultra-high-intensity synchrotron radiation is thus an important improvement in the technique for determination of structure through protein crystallography as well as in other cases where crystal size is often a limiting factor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lifetimes and spatio-temporal response of protein crystals in intense X-ray microbeams

Serial synchrotron-based crystallography using intense microfocused X-ray beams, fast-framing detectors and protein microcrystals held at 300 K promises to expand the range of accessible structural targets and to increase overall structure-pipeline throughputs. To explore the nature and consequences of X-ray radiation damage under microbeam illumination, the time-, dose- and temperature-depende...

متن کامل

Industry-relevant magnetron sputtering and cathodic arc ultra-high vacuum deposition system for in situ x-ray diffraction studies of thin film growth using high energy synchrotron radiation.

We present an industry-relevant, large-scale, ultra-high vacuum (UHV) magnetron sputtering and cathodic arc deposition system purposefully designed for time-resolved in situ thin film deposition/annealing studies using high-energy (>50 keV), high photon flux (>10(12) ph/s) synchrotron radiation. The high photon flux, combined with a fast-acquisition-time (<1 s) two-dimensional (2D) detector, pe...

متن کامل

VUV irradiation effects on proteins in high-flux synchrotron radiation circular dichroism spectroscopy.

Synchrotron radiation circular dichroism (SRCD) spectroscopy is emerging as an important new tool in structural molecular biology. Previously we had shown that in lower-flux SRCD instruments, such as UV1 at ISA and beamline 3.1 at the SRS, vacuum ultraviolet (VUV) radiation damage to proteins was not evident after exposure over a period of hours. No effects were detected in either the protein p...

متن کامل

How does radiation damage in protein crystals depend on X-ray dose?

Is radiation damage to cryopreserved protein crystals strictly proportional to accumulated dose at the high-flux density of beams from undulators at third-generation synchrotron sources? The answer is "yes," for overall damage to several different kinds of protein crystals at flux densities up to 10(15) ph/sec/mm(2) (APS beamline 19-ID). We find that, at 12 keV (1 A wavelength), about ten absor...

متن کامل

A Review of the Applications of Synchrotron Radiation in Archaeological Sciences

The scientific research regarding investigation, characterization and protection of the archeological specimens is manifested through a notable participation of multidisciplinary subjects and experts, scientists and archeometrists. One of the main principals which are considered by archaeometrists in the study of the precious specimens is the utilizing nondestructive methods. As an example, in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the National Academy of Sciences of the United States of America

دوره 82 22  شماره 

صفحات  -

تاریخ انتشار 1985