Calibrating physical activity intensity for hip-worn accelerometry in women age 60 to 91 years: The Women's Health Initiative OPACH Calibration Study
نویسندگان
چکیده
OBJECTIVE We conducted a laboratory-based calibration study to determine relevant cutpoints for a hip-worn accelerometer among women ≥60 years, considering both type and filtering of counts. METHODS Two hundred women wore an ActiGraph GT3X+ accelerometer on their hip while performing eight laboratory-based activities. Oxygen uptake was measured using an Oxycon portable calorimeter. Accelerometer data were analyzed in 15-second epochs for both normal and low frequency extension (LFE) filters. Receiver operating characteristic (ROC) curve analyses were used to calculate cutpoints for sedentary, light (low and high), and moderate to vigorous physical activity (MVPA) using the vertical axis and vector magnitude (VM) counts. RESULTS Mean age was 75.5 years (standard deviation 7.7). The Spearman correlation between oxygen uptake and accelerometry ranged from 0.77 to 0.85 for the normal and LFE filters and for both the vertical axis and VM. The area under the ROC curve was generally higher for VM compared to the vertical axis, and higher for cutpoints distinguishing MVPA compared to sedentary and light low activities. The VM better discriminated sedentary from light low activities compared to the vertical axis. The area under the ROC curves were better for the LFE filter compared to the normal filter for the vertical axis counts, but no meaningful differences were found by filter type for VM counts. CONCLUSION The cutpoints derived for this study among women ≥60 years can be applied to ongoing epidemiologic studies to define a range of physical activity intensities.
منابع مشابه
The Objective Physical Activity and Cardiovascular Disease Health in Older Women (OPACH) Study
BACKGROUND Limited evidence exists to inform physical activity (PA) and sedentary behavior guidelines for older people, especially women. Rigorous evidence on the amounts, intensities, and movement patterns associated with better health in later life is needed. METHODS/DESIGN The Objective PA and Cardiovascular Health (OPACH) Study is an ancillary study to the Women's Health Initiative (WHI) ...
متن کاملCalibration and Validation of a Wrist- and Hip-Worn Actigraph Accelerometer in 4-Year-Old Children
INTRODUCTION To determine time spent at different physical activity intensities, accelerometers need calibration. The aim of this study was to develop and cross-validate intensity thresholds for the Actigraph GT3X+ accelerometer for wrist and hip placement in four-year-old children. METHODS In total 30 children (49 months, SD 3.7) were recruited from five preschools in Stockholm. Equipped wit...
متن کاملExploring the challenges in obtaining physical activity data from women using hip-worn accelerometers.
Quality objective physical activity data are required to inform physical activity-based health improvement initiatives, however, various challenges undermine acquisition of such data. We examined the efficacy and challenges of a hip-worn accelerometry protocol in women. Specific objectives included determining accelerometer-wear-compliance rates and understanding the barriers and acceptability ...
متن کاملBoth Light Intensity and Moderate‐to‐Vigorous Physical Activity Measured by Accelerometry Are Favorably Associated With Cardiometabolic Risk Factors in Older Women: The Objective Physical Activity and Cardiovascular Health (OPACH) Study
BACKGROUND The relationship between light intensity physical activity (PA), which is common in older adults, and cardiovascular disease (CVD) risk factors is unclear. This study examined associations of accelerometer-measured PA intensity with CVD risk factors in older women of different race-ethnicities. METHODS AND RESULTS Cross-sectional analyses were conducted in 4832 women (mean age 78.9...
متن کاملValidation of the Vivago Wrist-Worn accelerometer in the assessment of physical activity
BACKGROUND Most accelerometers are worn around the waist (hip or lower back) to assess habitual physical activity. Wrist-worn accelerometers may be an alternative to the waist-worn monitors and may improve compliance in studies with prolonged wear. The aim of this study was to validate the Vivago® Wrist-Worn Accelerometer at various intensities of physical activity (PA) in adults. METHODS Twe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -
تاریخ انتشار 2015