SNR enhancement of intermolecular double-quantum coherence MRS in inhomogeneous fields with phased array coils
نویسندگان
چکیده
Introduction To obtain high-resolution magnetic resonance spectra (MRS), a homogeneous magnetic field is prerequisite with conventional methods. However, magnetic field homogeneity in vivo is often degraded in a large volume of human or animal tissues or in volumes with mixed tissues. Intermolecular double-quantum coherences (iDQCs), have been used to remove the effect of static field inhomogeneity [1-3]. High-resolution MRS of whole cerebellum in humans was obtained via detecting iDQC signal using a CP birdcage head coil on a 3-T clinical scanner [3]. But, the low signal-to-noise (SNR) limits further applications of the iDQC method. Here, we try to improve the SNR of iDQC MRS through using a phased array head coil relative to CP head coil. Methods Experiments were carried out on a Siemens 3-T TIM Trio whole-body scanner. Both a standard CP birdcage head coil and a 32-channel phased array head coil were utilized for signal reception. The corresponding RF excitation was achieved with the CP head coil and the body coil respectively. A proton MRS phantom with cylindrical shape and metabolite composition similar to that of a normal human brain was used. A two-dimensional (2D) iDQC pulse sequence with PRESS localization module was employed to perform iDQC measurement [3]. The spectral width was 250 Hz with 128 increments for F1 dimension and was 1000 Hz for F2 dimension. A voxel volume of 60×60×60 mm was chosen with the voxel center located at isocenter unless otherwise specified. In order to mimic a circumstance of inhomogeneous magnetic field, shimming was intentionally misadjusted to produce a linewidth of about 60 Hz for the water resonance. The standard PRESS sequence was employed to acquire the conventional single-quantum signal. The PRESS was performed on a voxel volume of 60×60×60 mm in inhomogeneous field (described above) and on a voxel volume of 20×20×20 mm in homogeneous field. The raw data acquired with both localized 2D iDQC and PRESS sequences were saved and processed using custom-made software based on Matlab 6.5.0. The multichannel nonparametric singular value decomposition (SVD) algorithm was utilized to combine multiple spectra acquired with the 32-channel phased array coil [4,5]. Combining the signal from a phased array coil is to make a weighted sum of the n fids. This can be expressed as S(t) = ∑wjSj(t)/sqrt(∑⎯wjwj), where Sj(t) is the signal from the coil j, wj is the weighting factor, j represents coils with j = 1,2,...,n, and t represents time points with t = 1,2,...,m. The iDQC fid data matrix A was constructed as a mk×n matrix (2D matrix), where m is the number of measured data points in the fid for each t1, k is the number of t1 steps in the 2D iDQC experiment, and n is the number of coils. A comprises the sum of a signal term Ā and a noise term N, A = Ā + N. Then, a Rank 1 approximation of A using SVD, A = USV', is made. The signal vector can be estimated from the principle column of U. The weighting factor wj can be obtained in the principle column of V, or from the eigenvector corresponding to the largest eigenvalue of A'A. Results and Discussion The spectra in Fig. 1 were obtained using the 32-channel coil with a voxel volume of 60×60×60 mm in the inhomogeneous field of about 60 Hz for water resonance. The results from the CP head coil were not displayed due to their appearance similar as those from 32-channel coil. The 2D localized iDQC pulse sequence was performed using both CP head coil and 32-channel coil in the same/similar inhomogeneous field as in Fig. 1. The obtained 2D iDQC spectra (see the example in Fig. 1b) were counterclockwise rotated by 63.4°, then projected onto the F2 axis. The resulting 1D projection spectra are shown in Fig. 2c and d. They hold similar resolution as those in Fig. 2a and b which were acquired by PRESS in homogeneous field with the voxel volume of 20×20×20 mm. The three major metabolite peaks, NAA, Cr and Cho, are clearly resolved in Fig. 2c and d. In Fig. 2, both the PRESS and iDQC spectra from 32-channel coil have the SNR (defined as the ratio of NAA peak intensity to the standard deviation of signal in the region between 7.0 and 8.0 ppm) about twice of those from the CP head coil through comparing Fig. 2d to c and b to a. To investigate the influence of voxel position relative to the phased array coil on iDQC SNR, voxel center was moved away from isocenter 15 mm along the directions of head, foot, anterior, and posterior respectively (see the schematic position of voxel center relative to coil in Fig. 3). The gain of iDQC SNR in the 32-channel over the CP head coils ranges from 1.6 to 2.5 times (see the detailed values in Fig. 3) . The variation reflects the dependence of sensitivity of phased array coil on the distance between the coil and voxel, since the 32-channel coil is asymmetric in the coil element distribution along the directions of head-foot and anterior-posterior. These results suggest that enhancement of iDQC SNR can be achieved through using phased array coils. This will provide great help for iDQC applications of high-resolution in vivo spectroscopy in the presence of field inhomogeneity. The gain in SNR however can be dependent on the relative location of the voxels in the coil and caution is needed in spectrum quantification. Acknowledgments We are grateful to Drs. Tong Zhu and Mathews Jacob for helpful discussion. This work was partially supported by the NIH (NS41048), and the NNSF of China (10974164). References [1] Chen Z, et al. J. Am. Chem. Soc. 126:446-447 (2004). [2] Chen Z, et al. J. Chem. Phys. 130:084504 (2009). [3] Lin YQ, et al. Magn. Reson. Med. (2009) in press. [4] Sandgren N, et al. J. Magn. Reson. 175:79-91(2005). [5] Bydder M, et al. Magn. Reson. Imag. 26 :847-850 (2008). Fig. 1. (a) 1D PRESS spectrum acquired in the inhomogeneous field, (b) 2D iDQC spectrum acquired in the same inhomogeneous field as (a). Fig. 2 (a,b) PRESS spectra from a CP head coil (a) and a 32-channel coil (b) in homogeneous fields. (c,d) 1D iDQC accumulated projection spectra obtained using the CP head coil (c) and the 32-channel coil (d) in the same/similar inhomogeneous magnetic field as in Fig. 1. Fig. 3. Ratio of iDQC SNR of the 32-channel over CP head coils, with voxel centers at different positions as indicated. The rectangles represent voxel centers (the middle one coincides with the coil center.). The relative distance between coil and voxel centers are indicated by d.
منابع مشابه
Double Tuned 31P/1H Elliptical Transceiver Phased Array for the Human Brain Studies at 7 T
Introduction: The improved SNR at 7T provides significant advantages for both H and lower gyromagnetic nuclei such as P, Na and C (X nuclei). Double resonant volume head coils, based on both birdcage (1-3) and TEM (4) designs have been previously used at lower magnetic fields. However at 7T, transceiver phased arrays provide significant advantages for both B1 homogeneity and transmit efficiency...
متن کاملQuantitative Study of Liver Magnetic Resonance Spectroscopy Quality at 3T Using Body and Phased Array Coils with Physical Analysis and Clinical Evaluation
This study aims to investigate the quality difference of short echo time (TE) breathhold 1H magnetic resonance spectroscopy (MRS) of the liver at 3.0T using the body and phased array coils, respectively. In total, 20 pairs of single-voxel proton spectra of the liver were acquired at 3.0T using the phased array and body coils as receivers. Consecutive stacks of breathhold spectra were acquired u...
متن کاملSpecific coil design for SENSE: a six-element cardiac array.
In sensitivity encoding (SENSE), the effects of inhomogeneous spatial sensitivity of surface coils are utilized for signal localization in addition to common Fourier encoding using magnetic field gradients. Unlike standard Fourier MRI, SENSE images exhibit an inhomogeneous noise distribution, which crucially depends on the geometrical sensitivity relations of the coils used. Thus, for optimum s...
متن کاملMulti-channel Proton Spectroscopy of the Heart
Introduction Single-voxel (SV) proton magnetic resonance spectroscopy (H-MRS) has been shown to be a valuable tool for the non-invasive assessment of myocardial triglycerides (TG) [1]. Traditionally, single-element coils are used for signal reception. However, because of their limited spatial sensitivity, the accurate positioning of the coil element close to the region of interest, i.e. the hea...
متن کاملfMRI of auditory stimulation with intermolecular double-quantum coherences (iDQCs) at 1.5T.
An intermolecular double-quantum coherence (iDQC) imaging technique was used to study auditory activation in the human brain at 1.5T with a dual temporal lobe surface phased array coil and a quadrature head coil. Preliminary results demonstrate that it is feasible to obtain auditory activation maps using iDQC imaging at 1.5T, both in individual subjects using the surface coil array and with mul...