Why large-head metal-on-metal hip replacements are painful: the anatomical basis of psoas impingement on the femoral head-neck junction.
نویسندگان
چکیده
Large-head metal-on-metal total hip replacement has a failure rate of almost 8% at five years, three times the revision rate of conventional hip replacement. Unexplained pain remains a feature of this type of arthroplasty. All designs of the femoral component of large-head metal-on-metal total hip replacements share a unique characteristic: a subtended angle of 120° defining the proportion of a sphere that the head represents. Using MRI, we measured the contact area of the iliopsoas tendon on the femoral head in sagittal reconstruction of 20 hips of patients with symptomatic femoroacetabular impingement. We also measured the articular extent of the femoral head on 40 normal hips and ten with cam-type deformities. Finally, we performed virtual hip resurfacing on normal and cam-type hips, avoiding overhang of the metal rim inferomedially. The articular surface of the femoral head has a subtended angle of 120° anteriorly and posteriorly, but only 100° medially. Virtual surgery in a normally shaped femoral head showed a 20° skirt of metal protruding medially where iliopsoas articulates. The excessive extent of the large-diameter femoral components may cause iliopsoas impingement independently of the acetabular component. This may be the cause of postoperative pain with these implants.
منابع مشابه
1832 Current Concepts Review Impingement with Total Hip Replacement
he principles regarding impingement in the natural osseous (anatomic) hip put forth by Ganz et al. are similar in concept to what can occur in the prosthetic hip. To understand impingement, it is helpful to recognize the common mechanisms that cause mechanical abutment in both anatomic and prosthetic hips. In the anatomic hip joint, impingement is a mechanical abutment conflict between the bone...
متن کاملThe femoral head/neck offset and hip resurfacing.
Because the femoral head/neck junction is preserved in hip resurfacing, patients may be at greater risk of impingement, leading to abnormal wear patterns and pain. We assessed femoral head/neck offset in 63 hips undergoing metal-on-metal hip resurfacing and in 56 hips presenting with non-arthritic pain secondary to femoroacetabular impingement. Most hips undergoing resurfacing (57%; 36) had an ...
متن کامل[Resurfacing arthroplasty of the hip].
Resurfacing arthroplasty is regarded as an attractive method, especially for the young patient who needs a hip replacement. However, the high expectations regarding this new technique in THR must first be met. Earlier experiences with similar forms of surface replacement have led to high revision rates with early aseptic wear induced component loosening and neck fractures. Technical progresses ...
متن کاملNotching of the femoral stem neck in metal-on-metal total hip replacement: a case report.
We report a case of impingement in a metal-on-metal total hip replacement causing both notching of the femoral stem neck and aseptic loosening of the acetabular component. The acetabular component was inserted in excessive anteversion. The femoral stem and acetabular components were retrieved. A larger femoral head was used, and an acetabular component was placed in a less anteverted position. ...
متن کاملRisk of impingement and third-body abrasion with 28-mm metal-on-metal bearings.
BACKGROUND Concerns have been raised about the sequelae of metal-on-metal (MoM) bearings in total hip arthroplasty (THA). However, retrieval studies, which offer the best insight into the clinically relevant mechanisms of MoM wear, have followed predictable trends to date such as indicting cobalt-chromium (CoCr) metallurgy, cup design, high conformity between the head and cup, "steep cups," "mi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 93 7 شماره
صفحات -
تاریخ انتشار 2011