Sub-millimeter T2 weighted fMRI at 7 T: comparison of 3D-GRASE and 2D SE-EPI

نویسندگان

  • Valentin G. Kemper
  • Federico De Martino
  • An T. Vu
  • Benedikt A. Poser
  • David A. Feinberg
  • Rainer Goebel
  • Essa Yacoub
چکیده

Functional magnetic resonance imaging (fMRI) allows studying human brain function non-invasively up to the spatial resolution of cortical columns and layers. Most fMRI acquisitions rely on the blood oxygenation level dependent (BOLD) contrast employing T(*) 2 weighted 2D multi-slice echo-planar imaging (EPI). At ultra-high magnetic field (i.e., 7 T and above), it has been shown experimentally and by simulation, that T2 weighted acquisitions yield a signal that is spatially more specific to the site of neuronal activity at the cost of functional sensitivity. This study compared two T2 weighted imaging sequences, inner-volume 3D Gradient-and-Spin-Echo (3D-GRASE) and 2D Spin-Echo EPI (SE-EPI), with evaluation of their imaging point-spread function (PSF), functional specificity, and functional sensitivity at sub-millimeter resolution. Simulations and measurements of the imaging PSF revealed that the strongest anisotropic blurring in 3D-GRASE (along the second phase-encoding direction) was about 60% higher than the strongest anisotropic blurring in 2D SE-EPI (along the phase-encoding direction). In a visual paradigm, the BOLD sensitivity of 3D-GRASE was found to be superior due to its higher temporal signal-to-noise ratio (tSNR). High resolution cortical depth profiles suggested that the contrast mechanisms are similar between the two sequences, however, 2D SE-EPI had a higher surface bias owing to the higher T(*) 2 contribution of the longer in-plane EPI echo-train for full field of view compared to the reduced field of view of zoomed 3D-GRASE.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cortical Depth Dependent Functional Responses in Humans at 7T: Improved Specificity with 3D GRASE

Ultra high fields (7T and above) allow functional imaging with high contrast-to-noise ratios and improved spatial resolution. This, along with improved hardware and imaging techniques, allow investigating columnar and laminar functional responses. Using gradient-echo (GE) (T2* weighted) based sequences, layer specific responses have been recorded from human (and animal) primary visual areas. Ho...

متن کامل

Cortical layer-dependent BOLD and CBV responses measured by spin-echo and gradient-echo fMRI: insights into hemodynamic regulation.

Spatial specificity of functional magnetic resonance imaging (fMRI) signals to sub-millimeter functional architecture remains controversial. To investigate this issue, high-resolution fMRI in response to visual stimulus was obtained in isoflurane-anesthetized cats at 9.4 T using conventional gradient-echo (GE) and spin-echo (SE) techniques; blood oxygenation-level dependent (BOLD) and cerebral ...

متن کامل

T2-weighted BOLD fMRI at 9.4 T using a S2-SSFP-EPI sequence

Introduction: It has been hypothesized that T2-weighted BOLD fMRI at ultra-high field shows higher spatial specificity than T2*weighted BOLD, since the main signal contribution is expected to come from the extravascular spins of the microvasculature [1-3]. Unfortunately, the number of slices that can be acquired in multi-slice SE-EPI is often highly limited at ultra-high field due to SAR constr...

متن کامل

3D single-shot VASO fMRI using a Maxwell-gradient compensated GRASE sequence

Introduction and Theory The vascular space occupancy (VASO) method [1] was recently proposed as the first fMRI method capable of detecting activation related CBV changes, without the need for a blood-pool contrast agent. We here present a new whole-brain VASO technique based on a parallel-accelerated single-shot 3D GRASE sequence. Furthermore, we propose a flow-compensated correction for concom...

متن کامل

Evaluation of Sensory Pathways in Spinal Cord by Comparison of fMRI Methodologies

Introduction: Today, clinicians and neuroscientists need to have a comprehensive survey of neurological pathologies and injuries. For the First-time, SEEP contrast and Spin-Echo pulse sequences was used for functional imaging of the Lumbar spinal cord. This method used by several research groups for Spinal cord mapping, but other researchers tried to improve BOLD fMRI to Spina...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015