Heterogeneity of response to constant positive pressure in patients with heart failure and coexisting central and obstructive sleep apnea: why?
نویسندگان
چکیده
The ventilatory treatment of patients with heart failure (HF) associated with obstructive sleep apnea (OSA), central sleep apnea (CSA), and Cheyne-Stokes respiration (CSR) remains debated. In a recent study in CHEST (August 2012), Randerath and colleagues 1 compared the effi ciency of auto-servoventilation (ASV) and CPAP in these patients. They report that ASV is superior to CPAP in improving CSA/CSR and N-terminal pro brain natriuretic peptide levels. As in previously published studies, 2 , 3 they observed a heterogeneity of response to CPAP on central and periodic apnea-hypopnea indi ces. In our opinion, at least two hypotheses may explain this heterogeneity of response and need to be evaluated in future studies. First, the level of pressure in the CPAP group may have infl uenced the results on an “individual basis,” although there is no statistical difference in the level of end-expiratory pressure between the CPAP group and the ASV group (mean CPAP, 10.3 1.0 cm H 2 O, mean expiratory positive airway pressure in ASV group, 8.4 1.7 cm H 2 O). As shown previously, 4 there is a heterogeneous effect of CPAP on cardiac output, depending on the patient and the level of pressure. A neg ative hemodynamic impact of CPAP on the heart could aggravate the vicious cycle of HF-CSA/CSR. Considering the high levels of N-terminal pro brain natriuretic peptide in the patients treated with CPAP reported by Randerath and colleagues, 1 it would be interesting to evaluate on an “individual basis” the impact of CPAP on heart hemodynamics and correlate this result with the residual central and periodic apnea-hypopnea indices. Second, the distribution of the central events during the night may also have infl uenced the results. Two types of patients can be observed in the situation of coexisting OSA/CSA/CSR and HF. Some patients have central events throughout the night, whereas some have central events only at the end of the night. 5 These latter patients have a better response to CPAP; central events at that time are the consequence of transient cardiac dysfunction induced by the obstructive events of the beginning of the night. Correction of the obstructive events avoids cardiac dysfunction and central events induced. In our experience, the need to change CPAP to ASV because of the persistence of central events is unusual in this subtype of patients, whereas it is common if the central events are distributed throughout the night. In conclusion, future studies will determine the predictive factors of failure or success of CPAP in patients with HF and coexisting OSA/CSA/CSR.
منابع مشابه
Probability of obstructive sleep apnea in male patients with systolic heart failure and some related factors
Background and Purpose: Sleep breathing disorders have a negative impact on the illness outcome and quality of life in patients with heart failure. This study was conducted to investigate the probability of obstructive sleep apnea in men with heart failure and some related factors. Method: This was a cross-sectional study conducted on 100 male patients with systolic heart failure selected throu...
متن کاملEffect of flow-triggered adaptive servo-ventilation compared with continuous positive airway pressure in patients with chronic heart failure with coexisting obstructive sleep apnea and Cheyne-Stokes respiration.
BACKGROUND In patients with chronic heart failure (CHF), the presence of sleep-disordered breathing, including either obstructive sleep apnea or Cheyne-Stokes respiration-central sleep apnea, is associated with a poor prognosis. A large-scale clinical trial showed that continuous positive airway pressure (CPAP) did not improve the prognosis of such patients with CHF, probably because of insuffi...
متن کاملSex matters in pulmonary arterial hypertension.
systolic heart failure and concomitant diastolic dysfunction: subanalysis of a randomized controlled trial. Respiration 2014; 87: 54–62. 3 Fietze I, Blau A, Glos M, et al. Bi-level positive pressure ventilation and adaptive servo ventilation in patients with heart failure and Cheyne-Stokes respiration. Sleep Med 2008; 9: 652–659. 4 Kasai T, Usui Y, Yoshioka T, et al. Effect of flow-triggered ad...
متن کاملEffects of Biofeedback Therapy on Cardiovascular and Respiratory Indices in NREM Sleep Parasomnias with Obstructive Sleep Apnea: A Case study
Introduction: Non-REM parasomnias are a relatively common condition in the general human population. Current treatment plans are usually based on small case series and reports. Considering the effects of sleep disorders on different aspects of human life and the failure of pharmacological treatments in this field, the present study was designed to investigate a case of this sleep disorders with...
متن کاملFactors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach
Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 143 6 شماره
صفحات -
تاریخ انتشار 2013