A simulation study to evaluate limited sampling strategies to estimate area under the curve of drug concentration versus time following repetitive oral dosing: limited sampling model versus naive trapezoidal method.
نویسندگان
چکیده
The area under the curve (AUC) can be associated with the therapeutic or toxic effect of a drug. The limited sampling model (LSM) is an approach that is gaining popularity due to its simplicity for the estimation of AUC using 1-3 blood samples. The aim of the present simulation study was to compare the performance of LSM for various hypothetical drugs with that of the naive trapezoidal method (Trap). The 3-point (trough, peak, and downhill) sampling design following repetitive oral dosing was assumed for LSM (LSM3) and Trap (Trap3). The 2-point (trough and peak) sampling design was also assumed for LSM (LSM2) and Trap (Trap2). In addition, trough-sampling and peak-sampling designs for LSM were designated as LSM1 and LSM1', respectively. As a result, the rank order of precision of the AUC estimation designs/methods was summarized as follows: LSM3 asymptotically equal to Trap3> or =LSM2> or =Trap2 asymptotically equal to LSM1>LSM1'. The finding suggested that LSM can not always improve the estimation performance of AUC in the 3-point sampling design, and that LSM1' is insufficient to estimate the performance of AUC for the hypothetical drugs evaluated in the present study. Accordingly, LSM2 and LSM1 may be an efficient approach for estimating AUC following repetitive oral dosing. In addition, Trap3 and Trap2 may be promising alternatives, because Trap does not require a high investment to recruit a full-sampling model-development group.
منابع مشابه
Limited sampling strategy for patient-oriented clinical pharmacokinetic trial.
Clinical pharmacologists (-kinetists) are charged with the obligation to quantify dose-response relationships (pharmacokinetics and pharmacodynamics) of clinically useful drugs. Clinical pharmacokinetic studies are performed to determine the rational use of medicines according to patient characteristics, such as disease and genotype of drug metabolizing enzymes (transporters), and predict the i...
متن کاملEvaluation of Cyclosporine Pharmacokinetic, Monitoring, and Dosing Parameters for GVHD Prophylaxis in Hematopoietic Stem Cell Transplant (HSCT) Recipients
Allogeneic hematopoietic stem cell transplantation (AHSCT) is a major method of treatmentfor different hematologic and congenital disease. Graft versus host disease (GvHD) is a lifethreateningadverse effect of AHSCT. Cyclosporine is the most important and common agentfor GvHD prophylaxis. Because of variable and unpredictable pharmacokinetics of cyclosporinethat produces...
متن کاملEvaluation of Cyclosporine Pharmacokinetic, Monitoring, and Dosing Parameters for GVHD Prophylaxis in Hematopoietic Stem Cell Transplant (HSCT) Recipients
Allogeneic hematopoietic stem cell transplantation (AHSCT) is a major method of treatmentfor different hematologic and congenital disease. Graft versus host disease (GvHD) is a lifethreateningadverse effect of AHSCT. Cyclosporine is the most important and common agentfor GvHD prophylaxis. Because of variable and unpredictable pharmacokinetics of cyclosporinethat produces...
متن کاملOptimal sampling and limited sampling strategies for estimation of unbound platinum AUC after nedaplatin infusion.
The aim of this study was to determine the optimal sampling design for empirical Bayesian forecasting for nedaplatin, and also to develop a simple formula for estimating the area under the plasma concentration-time curve (AUC) of platinum which relates to hematological toxicity after nedaplatin dosing using limited sampling points. Plasma unbound platinum concentration data were retrospectively...
متن کاملLimited sampling strategies to estimate the area under the concentration-time curve. Biases and a proposed more accurate method.
BACKGROUND Over 100 limited sampling strategies (LSSs) have been proposed to reduce the number of blood samples necessary to estimate the area under the concentration-time curve (AUC). The conditions under which these strategies succeed or fail remain to be clarified. OBJECTIVES We investigated the accuracy of existing LSSs both theoretically and numerically by Monte Carlo simulation. We also...