Acoustic radiation force impulse imaging of kidneys – a phantom study
نویسندگان
چکیده
AIM OF THE STUDY Since there have been only few works reporting the diagnosis of kidneys using Acoustic Radiation Force Impulse technique and those works do not provide consistent results of shear wave velocity measurements in renal tissue, we have decided to use kidney phantoms with known properties to examine the reliability of the method itself in a controlled setup similar to kidneys examination. MATERIALS AND METHODS Four gelatin-based phantoms imitating different clinical situations were manufactured - two with thick and two with thin renal cortex, each type at a depth similar to a normal-weight or overweight patient. For each phantom, a series of interest points was chosen and for each point 20 Shear Wave Velocity measurements were taken using the build-in Virtual Touch Tissue Quantification™ tool in a Siemens Acuson S2000 ultrasound scanner equipped with a 6C1 HD Transducer (Siemens Mountainview, USA). RESULTS Mean Shear Wave Velocity values obtained for all the examined points ranged from 2.445 to 3.941 m/s, with standard deviation exceeding 0.1 in only one case out of 29 points, but differing significantly between all points. CONCLUSIONS The obtained results indicate that the method is highly reliable as long as the measurement volume contains a uniform tissue region. If the measurement window covers a region with different properties even partially, the obtained results are affected. The variance of measured values on the other hand is not affected by the said non-uniformity of material under examination. Furthermore, the variance of measured values does not show a clear dependency on the depth at which the shear wave velocities are measured.
منابع مشابه
Solid appearance of pancreatic serous cystadenoma diagnosed as cystic at ultrasound acoustic radiation force impulse imaging.
CONTEXT Acoustic radiation force impulse imaging is an emerging imaging modality. The study of the pancreas is a new and promising application of ultrasound acoustic radiation force impulse imaging. CASE REPORT We present the first case of pancreatic serous cystadenoma which mimics a solid neoplasm at conventional imaging (US and CT), correctly diagnosed as cystic at ultrasound acoustic radia...
متن کاملAcoustic Radiation Force Impulse Imaging of Myocardial Performance
(Biomedical Engineering) Acoustic Radiation Force Impulse Imaging of Myocardial Performance
متن کاملPassive hepatic congestion: Findings of two-dimensional, Doppler, and acoustic radiation force impulse imaging
متن کامل
On the importance of modelling organ geometry and boundary conditions for predicting three-dimensional prostate deformation.
The use of an ultrasound probe or a needle guide during biopsy deforms both the rectal wall and the prostate, resulting in lesion motion. An accurate patient-specific finite element (FE)-based biomechanical model can be used to predict prostate deformations. In this study, an FE model of a prostate phantom is developed using magnetic resonance images, while soft-tissue elasticity is estimated i...
متن کاملShear wave velocity measurements using acoustic radiation force impulse in young children with normal kidneys versus hydronephrotic kidneys
PURPOSE To measure shear wave velocities (SWVs) by acoustic radiation force impulse (ARFI) ultrasound elastography in normal kidneys and in hydronephrotic kidneys in young children and to compare SWVs between the hydronephrosis grades. METHODS This study was approved by an institutional review board, and informed consent was obtained from the parents of all the children included. Children und...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2016