A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study

نویسندگان

  • Fauzia Ashraf
  • Pushpa Shankarappa
  • Abhinav Misra
  • Asheesh Sawhney
  • Nandamuri Sridevi
  • Anu Singh
چکیده

Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acrylic tube with simulated periodontal ligaments and the apex was exposed. The root canals were instrumented with different rotary files, namely, ProTaper Universal, ProTaper Next, and HyFlex CM, to the major apical foramen (AF), short AF, and beyond AF. The root apex was stained with 1% methylene blue dye and digital images of apical surface of every tooth were taken and development of dentinal defects was determined by using stereomicroscope. Multinomial logistic regression test was performed to identify influencing factors. Results. Instrumentation with rotary files terminated 2 mm short AF and did not cause any cracks. Significantly less cracks were seen when instrumentation with rotary files terminated 1 mm short apical foramen when compared with the instrumentation terminated at or beyond apical foramen (p < 0.05). Conclusion. ProTaper Universal rotary files caused more dentinal cracks than ProTaper Next and HyFlex CM. Instrumentation short AF reduced the risk of dentinal defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stereomicroscopic Evaluation of Radicular Dentinal Defects after Using EDTA Gel with Different Rotary Systems: An In-Vitro Study

The purpose of the present study was to study the occurrence of radicular dentinal defects after using EDTA gel during preparation of the root canal with ProTaper Universal (Dentsply Maillefer, Switzerland), HyFlex (ColteneWhaledent, Allstetten, Switzerland), and ProTaper Next (Dentsply Maillefer) rotary instruments. Forty-eight single rooted premolars were selected. Twelve teeth were instrumen...

متن کامل

Effects of ProTaper Universal, ProTaper Next, and HyFlex instruments on crack formation in dentin.

INTRODUCTION The aim of the present study was to investigate the incidence of cracks in root dentin after root canal preparation with ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland), HyFlex (Coltene-Whaledent, Allstetten, Switzerland), and ProTaper Universal (Dentsply Maillefer) rotary instruments. METHODS One-hundred mandibular premolars were selected. Twenty-five teeth were left...

متن کامل

Evaluation Of Apical Transportation Using 3 Different Rotary Systems: Hyflex Files, Twisted Files, Protaper Next By Morphometric Analysis

Aim: This in vitro study was performed to evaluate the apical transportation between Hyflex files, Twisted files and Protaper next single file rotary system by motic imaging. Materials & Methods: Sixty Endo Training Blocks were used in the study. Pre instrumentation photos of the simulated apical foramen are recorded using an optical microscope and then coupled into the motic imaging software a...

متن کامل

Vertical Root Fracture initiation in curved roots after root canal preparation: A dentinal micro-crack analysis with LED transillumination

Background One of the causative factors of root defects is the increased friction produced by rotary instrumentation. A high canal curvature may increase stress, making the tooth more susceptible to dentinal cracks. The purpose of this study was to evaluate dentinal micro-crack formation with the ProTaper NEXT and ProTaper Universal systems using LED transillumination, and to analyze the micro-...

متن کامل

An in vitro comparison of apically extruded debris and instrumentation times with ProTaper Universal, ProTaper Next, Twisted File Adaptive, and HyFlex instruments.

INTRODUCTION The purpose of this study was to compare the in vitro amount of apically extruded debris with new endodontic rotary nickel-titanium instruments. METHODS Sixty mandibular premolars were instrumented up to size 25 using ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (Dentsply Maillefer), Twisted File Adaptive (SybronEndo, Orange, CA), and HyFlex (Co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016