Hemodynamic numerical simulations of the disturbance due to intracoronary flow measurements by a Doppler guide wire

نویسندگان

  • Kamil J. Chodzyński
  • Simone Gremmo
  • Omer F. Eker
  • Jacques Lalmand
  • Adel Aminian
  • Daniel Ribeiro de Sousa
  • Karim Zouaoui Boudjeltia
  • Grégory Coussement
چکیده

BACKGROUND Since hemodynamics plays a key role in the development and evolution of cardiovascular pathologies, physician's decision must be based on proper monitoring of relevant physiological flow quantities. METHODS A numerical analysis of the error introduced by an intravascular Doppler guide wire on the peak velocity measurements has been carried out. The effect of probe misalignment (±10°) with respect to the vessel axis was investigated. Numerical simulations were performed on a realistic 3D geometry, reconstructed from coronary angiography images. Furthermore, instead of using Poiseuille or Womersley approximations, the unsteady pulsatile inlet boundary condition has been calculated from experimental peak-velocity measurements inside the vessel through a new approach based on an iterative Newton's algorithm. RESULTS The results show that the presence of the guide modifies significantly both the maximum velocity and the peak position in the section plane; the difference is between 6 and 17 % of the maximum measured velocity depending on the distance from the probe tip and the instantaneous vessel flow rate. Furthermore, a misalignment of the probe may lead to a wrong estimation of the peak velocity with an error up to 10 % depending on the probe orientation angle. CONCLUSIONS The Doppler probe does affect the maximum velocity and its position during intravascular Doppler measurements. Moreover, the Doppler-probe-wire sampling volume at 5.2 and 10 mm far from the probe tip is not sufficient to prevent its influence on the measurement. This should be taken into account in clinical practice by physicians during intravascular Doppler quantification. The new numerical approach used in this work could potentially be helpful in future numerical simulations to set plausible inlet boundary conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of coronary flow velocity dynamics and flow reserve in patients with Kawasaki disease by means of a Doppler guide wire.

OBJECTIVES To assess the pathophysiologic effects of the coronary sequelae of Kawasaki disease on coronary hemodynamic variables, we regionally evaluated the flow velocity dynamics and flow reserve in coronary vessels with lesions using an intracoronary Doppler flow guide wire. BACKGROUND The pathophysiologic effects of the coronary sequelae of Kawasaki disease on coronary hemodynamic variabl...

متن کامل

Transesophageal versus intracoronary Doppler measurements for calculation of coronary flow reserve.

OBJECTIVE The present study was performed to compare coronary flow reserve by transesophageal Doppler echocardiography and intracoronary Doppler flow wire measurements in patients with LAD disease. METHODS 17 patients with various degree of LAD stenosis were studied. Intracoronary LAD Doppler measurements were performed at baseline and after intracoronary injection of 18 micrograms adenosine....

متن کامل

Coronary hyperemic dose responses of intracoronary sodium nitroprusside.

BACKGROUND Sodium nitroprusside is one of several agents considered effective for treating the no-reflow phenomenon during acute coronary interventions. However, the coronary hyperemic dose responses and systemic hemodynamic effects of intracoronary nitroprusside have yet to be determined in humans. The purpose of this study was to compare the hyperemic and hemodynamic responses of intracoronar...

متن کامل

3D Numerical Simulation of the Separated Turbulent Shallow Flow around a Single Side Obstacle

In this paper, the performance of Reynolds Averaged Navier Stokes (RANS) simulations was evaluated to predict the flow structure developed by the presence of a sidewall obstruction in a uniform open-channel shallow flow. The study of these flow structures is important because they present in several real world configurations, such as groynes in rivers, where the erosion processes, mass transpor...

متن کامل

LDA Experimental Data of Three-Poster Jet Impingement System

During its near-ground hovering phase a Short Take-Off and Vertical Landing (STOVL) aircraft creates a complex three-dimensional flow field between jet streams, the airframe surface and the ground. A proper understanding and numerical prediction of this flow is important in the design of such aircraft. In this paper an experimental facility, used to gather validation data suitable for testing C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2016