Evaluation of the TEST 1 erythrocyte sedimentation rate system and intra- and inter-laboratory quality control using new latex control materials.
نویسندگان
چکیده
BACKGROUND The erythrocyte sedimentation rate (ESR) test has been considered to be a simple procedure, not requiring quality control (QC). However, QC is essential for accuracy and precision. We evaluated the TEST 1 ESR system and performed QC procedures using newly developed latex control materials in three hospitals. METHODS Using tripotassium ethylenediaminetetraacetic acid blood samples (n=184), we compared TEST 1 ESR values with Westergren ESR data and evaluated intra-assay precision. Three levels of latex control materials were used to assess inter-assay precision. Reference range assessment was done using samples from 220 healthy individuals. Inter-laboratory QC with latex control materials in three hospitals was performed. RESULTS Correlation between TEST 1 ESR and Westergren ESR results was good (p<0.001). Intra-assay precision [coefficients of variation (CV) 6.6%-21.7%] with patient samples and inter-assay precision (CV 0.0%-6.8%) with latex control materials were satisfactory. The reference ranges of 2-10 mm/h for males and 2-19 mm/h for females were established. Inter-laboratory QC data with latex control materials in three hospitals demonstrated good accuracy and satisfactory precision (CV 0.0%-14.4%). CONCLUSIONS Our results demonstrate that the TEST 1 QC is reliable and the latex control materials are valuable for inter-laboratory proficiency testing.
منابع مشابه
Aberration of Erythrocyte Sedimentation Rate by Zinc Nanoparticles
Dear Editor, erythrocyte sedimentation rate (ESR) is a useful basic clinical pathology laboratory investigation. It can be helpful in diagnosis and follow-up of several diseases. At present, a new automated method with proven reliability is available for ESR test (1). Here, the authors report on observation on a laboratory experiment to test the effect of zinc nanoparticles on ESR results. The...
متن کاملInternal Quality Control for Erythrocyte Sedimentation Rate Using Patient Blood Sample
The erythrocyte sedimentation rate (ESR) test continues to be used as an important tool in many laboratories; either manually or as automated method. When automation is applied in clinical laboratories, it is imperative that reliable methods for calibration and appropriate control materials are available for monitoring the accuracy and precision of the results generated. But when the commercial...
متن کاملErythrocyte sedimentation rate: use of fresh blood for quality control.
The erythrocyte sedimentation rate (ESR) remains the most widely used laboratory test for monitoring the course of infections, inflammatory diseases, and some types of cancer. Several test methods have been developed recently, and as a result the safety and reliability of ESR testing procedures have improved. The method recommended by the International Council for Standardization in Haematology...
متن کاملThe latex slide test in rheumatic disorders.
The latex slide test (L.S.T.) has been shown to be simple to perform and easy to read. It gives results comparable with the more complicated serological procedures used in the diagnosis of rheumatoid arthritis.In 603 cases the L.S.T. and differential agglutination test gave a high degree of correlation. There were only four discrepancies between the two tests. The L.S.T. is the more practicable...
متن کاملSurvey on Laboratory Test Quality Control Establishment in Public and Private Medical Laboratories in Hamedan Province
Introduction: The purpose of laboratory test quality control establishment is to ensure the daily stability of the test system. Considering the defined principles guarantees laboratory performance improvement and patients’ confidence in the results of their tests. This study was conducted to survey laboratory test quality control establishment in public and private medical laboratories in Hamed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 48 7 شماره
صفحات -
تاریخ انتشار 2010