Independent System Calibration of Sentinel-1B

نویسندگان

  • Marco Schwerdt
  • Kersten Schmidt
  • Nuria Tous-Ramon
  • Patrick Klenk
  • Nestor Yague-Martinez
  • Pau Prats
  • Manfred Zink
  • Dirk Geudtner
چکیده

Sentinel-1B is the second of two C-Band Synthetic Aperture Radar (SAR) satellites of the Sentinel-1 mission, launched in April 2016—two years after the launch of the first satellite, Sentinel-1A. In addition to the commissioning of Sentinel-1B executed by the European Space Agency (ESA), an independent system calibration was performed by the German Aerospace Center (DLR) on behalf of ESA. Based on an efficient calibration strategy and the different calibration procedures already developed and applied for Sentinel-1A, extensive measurement campaigns were executed by initializing and aligning DLR’s reference targets deployed on the ground. This paper describes the different activities performed by DLR during the Sentinel-1B commissioning phase and presents the results derived from the analysis and the evaluation of a multitude of data takes and measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Assessment of Sentinel-1A Data for Surface Soil Moisture Estimations Using a Coupled Water Cloud Model and Advanced Integral Equation Model over the Tibetan Plateau

The spatiotemporal distribution of soil moisture over the Tibetan Plateau is important for understanding the regional water cycle and climate change. In this paper, the surface soil moisture in the northeastern Tibetan Plateau is estimated from time-series VV-polarized Sentinel-1A observations by coupling the water cloud model (WCM) and the advanced integral equation model (AIEM). The vegetatio...

متن کامل

The Internal and External Calibration of the Sentinel-1 CSAR

The ESA Sentinels constitute the first series of operational satellites responding to the Earth Observation needs of the EU-ESA Global Monitoring for Environment and Security (GMES) programme. The GMES space component relies on existing and planned space assets as well as on new complementary developments by ESA. This paper describes the in-orbit calibration aspects for the Sentinel-1 mission. ...

متن کامل

Calibration of Dual Polarimetric C-band Sar Data: a Possible Approach for Sentinel-1

In this paper we discuss the radiometric calibration of dual polarimetric Synthetic Aperture Radar (SAR) data. The polarimetric distortion model of a dualpol SAR includes four calibration complex parameters: the cross-talk on transmit, the receiving channel imbalance and two receiving cross-talks. While these parameters can be estimated in a full-pol system using distributed targets with reflec...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

Alteration of Serum Levels of Interlukin 1 and Tumor Necrosis Factor in Depression Independent of Treatment or Overdose of Tricyclic Antidepressants

Introduction: Pro-inflammatory cytokines, such as IL-1b and TNF- α have been suggested to be involved in the pathophysiology of depression. Tricyclic antidepressants (TCAs) are also thought to influence immune functions and concentrations of cytokines. The aim of this study was to evaluate the status of serum IL-1b and TNF-α in depressed patients who were treated, not treated, or poisoned wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Remote Sensing

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017