Respiratory inductance plethysmography in healthy infants: a comparison of three calibration methods.
نویسندگان
چکیده
Respiratory inductance plethysmography (RIP) measures respiration from body surface movements. Various techniques have been proposed for calibration in order that RIP may be used quantitatively. These include calculation of the proportionality constant of ribcage to abdominal volume change (K). The aims of this study were to 1) establish whether a fixed value of K could be used for calibration, and 2) compare this technique with multiple linear regression (MLR) and qualitative diagnostic calibration (QDC) in normal healthy infants. Recordings of pneumotachograph (PNT) flow and RIP were made during quiet (QS) and active sleep (AS) in 12 infants. The first 5 min in a sleep state were used to calculate calibration factors, which were applied to subsequent validation data. The absolute percentage error between RIP and PNT tidal volumes was calculated. The percentage error was similar over a wide range of K during QS. However, K became more critical when breathing was out of phase. A standard for K of 0.5 was chosen. There was good agreement between calibration methods during QS and AS. In the first minute following calibration during QS, the mean absolute errors were 3.5, 4.1 and 5.3% for MLR, QDC and fixed K respectively. The equivalent errors in AS were 11.5, 13.1 and 13.7% respectively. The simple fixed ratio method can be used to measure tidal volume with similar accuracy to multiple linear regression and qualitative diagnostic calibration in healthy unsedated sleeping infants, although it remains to be validated in other groups of infants, such as those with respiratory disease.
منابع مشابه
Calibration of respiratory inductance plethysmograph in preterm infants with different respiratory conditions.
Respiratory inductance plethysmography (RIP) is a method for respiratory measurements particularly attractive in infants because it is noninvasive and it does not interfere with the airway. RIP calibration remains controversial in neonates, and is particularly difficult in infants with thoraco-abdominal asynchrony or with ventilatory assist. The objective of this study was to evaluate a new RIP...
متن کاملPressure sensor plethysmography: a method for assessment of respiratory motion in children.
Noncalibrated respiratory inductance plethysmography has been used to measure respiratory function by calculation of the phase angle and, more recently, by determination of the ratio of each time to reach peak tidal expiratory flow to total expiratory time (TPEF/TE). Since TPEF/TE is known to be decreased in airway obstruction when derived from flow signals obtained by a pneumotachograph, we wa...
متن کاملRespiratory inductive plethysmography: a comparative study between isovolume maneuver calibration and qualitative diagnostic calibration in healthy volunteers assessed in different positions.
OBJECTIVE To compare two methods of respiratory inductive plethysmography (RIP) calibration in three different positions. METHODS We evaluated 28 healthy subjects (18 women and 10 men), with a mean age of 25.4 ± 3.9 years. For all of the subjects, isovolume maneuver calibration (ISOCAL) and qualitative diagnostic calibration (QDC) were used in the orthostatic, sitting, and supine positions. I...
متن کاملElectromagnetic inductance plethysmography is well suited to measure tidal breathing in infants
Reliable, accurate and noninvasive methods for measuring lung function in infants are desirable. Electromagnetic inductance plethysmography has been used to perform infant spirometry and VoluSense Pediatrics (VSP) (VoluSense, Bergen, Norway) represents an updated version of this technique. We aimed to examine its accuracy compared to a validated system measuring airflow via a facemask using an ...
متن کاملVariability of end-expiratory lung volume in premature infants.
BACKGROUND Analysis of breath-to-breath variability of respiratory characteristics provides information on the respiratory control. In infants, the control of end-expiratory lung volume (EELV) is active and complex, and it can be altered by respiratory disease. The pattern of EELV variability may reflect the behavior of this regulatory system. OBJECTIVES We aimed to characterize EELV variabil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The European respiratory journal
دوره 16 6 شماره
صفحات -
تاریخ انتشار 2000