The neural signal for skin indentation depth. II. Steady indentations.

نویسندگان

  • J Mei
  • R P Tuckett
  • D A Poulos
  • K W Horch
  • J Y Wei
  • P R Burgess
چکیده

The glabrous skin of the monkey's hand was stimulated with a waveform that indented the skin at a rate of 0.4 mm/sec, held the skin steadily or nearly steadily indented for 12 sec or longer, and then retracted back to the starting position. Recordings were made of activity in single afferent fibers in response to these stimuli. The average discharge frequency of 21 slowly adapting mechanoreceptors declined 38% during the first 12 sec of a steady indentation when the amplitude of the displacement was 0.65 mm and 36% when the displacement was 1.3 mm. When the plateau was not steady but the indentation depth gradually decreased by 15% during the 12-sec plateau period, the average decline was 47% for the 0.65-mm indentation and 46% for the 1.3-mm stimulus. When the indentation depth gradually increased by 15% during the 12-sec plateau, the discharge declined an average of 26% during the 0.65-mm indentation and 22% during the 1.3-mm displacement. To determine the effect of receptor adaptation on the perception of skin indentation depth, 13 human subjects had the skin of their fingertips indented 1 mm with similar trapezoidal waveform and were asked whether the indentation depth increased or decreased during the plateau portion of the stimulus. Ten of the 13 subjects thought that the indentation depth was increasing when the plateau was steady. The method of limits was then used to determine how much the stimulus had to change for the subject to feel the depth during the plateau as unchanging; i.e., a "perceptual zero."(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The neural signal for skin indentation depth. I. Changing indentations.

Psychophysical tests on human subjects showed that judgments of skin indentation depth made when the fingertip was indented at rates from 0.2 to 16 mm/sec were quite insensitive to changes in indentation velocity. Similar results were obtained on the forearm at indentation velocities of 0.4 to 16 mm/sec. Recordings were made from mechanoreceptors in the monkey's hand that were able to respond o...

متن کامل

Surround suppression in the responses of primate SA1 and RA mechanoreceptive afferents mapped with a probe array.

Twenty-four slowly adapting type 1 (SA1) and 26 rapidly adapting (RA) cutaneous mechanoreceptive afferents in the rhesus monkey were studied with an array of independently controlled, punctate probes that covered an entire fingerpad. Each afferent had a receptive field (RF) on a single fingerpad and was studied at 73 skin sites (50 mm2). The entire array was lowered to 1.6 to 3.0 mm below the p...

متن کامل

Estimation of local anisotropy of plexiform bone: Comparison between depth sensing micro-indentation and Reference Point Indentation.

The recently developed Reference Point Indentation (RPI) allows the measurements of bone properties at the tissue level in vivo. The goal of this study was to compare the local anisotropic behaviour of bovine plexiform bone measured with depth sensing micro-indentation tests and with RPI. Fifteen plexiform bone specimens were extracted from a bovine femur and polished down to 0.05µm alumina pas...

متن کامل

SA1 and RA receptive fields, response variability, and population responses mapped with a probe array.

Twenty-four slowly adapting type 1 (SA1) and 26 rapidly adapting (RA) cutaneous mechanoreceptive afferents in the rhesus monkey were studied with an array of independently controlled, punctate probes that covered an entire fingerpad. Each afferent had a receptive field (RF) on a single fingerpad and was studied at 73 skin sites (50 mm2). The entire array was lowered to 1.6 mm below the point of...

متن کامل

Mechanical Properties of Evaporated Gold Films. Hard Substrate Effect Correction

Nanoindentation tests using the Berkovich indenter tip were performed on 50 and 200 nm thick polycrystalline gold films deposited on hard substrates. Gold film hardness increased with the indentation depth due to the influence of the substrate. A procedure based on the Joslin-Oliver method was introduced to correct for the substrate effect. The method utilizes the fact that the measured elastic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of neuroscience : the official journal of the Society for Neuroscience

دوره 3 12  شماره 

صفحات  -

تاریخ انتشار 1983