Applications of Hadamard transform to gas chromatography/mass spectrometry and liquid chromatography/mass spectrometry.

نویسندگان

  • Cheng-Huang Lin
  • Takashi Kaneta
  • Hung-Ming Chen
  • Wen-Xiong Chen
  • Hung-Wei Chang
  • Ju-Tsung Liu
چکیده

Successful application of the Hadamard transform (HT) technique to gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS) is described. Novel sample injection devices were developed to achieve multiple sample injections in both GC and LC instruments. Air pressure was controlled by an electromagnetic valve in GC, while a syringe pump and Tee connector were employed for the injection device in LC. Two well-known, abused drugs, 3,4-methylenedioxy-N-methylamphetamine (MDMA) and N, N-dimethyltryptamine (DMT), were employed as model samples. Both of the injection devices permitted precise successive injections, resulting in clearly modulated chromatograms encoded by Hadamard matrices. After inverse Hadamard transformation of the encoded chromatogram, the signal-to-noise (S/N) ratios of the signals were substantially improved compared with those expected from theoretical values. The S/N ratios were enhanced approximately 10-fold in HT-GC/MS and 6.8 in HT-LC/MS, using the matrices of 1023 and 511, respectively. The HT-GC/MS was successfully applied to the determination of MDMA in the urine sample of a suspect.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Applications of Hadamard transform-gas chromatography/mass spectrometry to online detection of exhaled breath after drinking or smoking.

A Hadamard transform-gas chromatography/mass spectrometry (HT-GC/MS) technique was employed for the online detection of ethanol or toluene in exhaled breath after drinking or smoking, respectively. Exhaled breath samples, collected from volunteers, were directly injected into the GC inlet by a Hadamard-injector without any pretreatment. In the case of breath from a drinker, using a conventional...

متن کامل

Comparative Pharmacokinetics of Berberine, Palmatine and Jatrorrhizine in Rat Plasma after Oral Administration of Rhizoma coptidis and Zuojinwan Using Liquid Chromatography-Tandem Mass Spectrometry

A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of berberine, palmatine and jatrorrhizine in rat plasma. Target compounds, together with the internal standard (metronidazole), were extracted from rat plasma samples by protein precipitation with acetonitrile-methanol (1:2, v/v). Chromatography was carried out using a ...

متن کامل

Simultaneous Analysis of Metabolite Residues from Degradation of Dithiocarbamates in Cereals Using Liquid Chromatography Coupled with Tandem Mass Spectrometry

Background and Objectives: Dithiocarbamates are groups of fungicides used to control pests of agricultural products. Analysis of these pesticides with liquid and gas chromatography instruments is associated with various problems due to the presence of metal groups in the structure of these compounds. Therefore, one of the ways for analysis the pesticides is to check the level of decomposition...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 80 15  شماره 

صفحات  -

تاریخ انتشار 2008