Access path angle in transapical aortic valve replacement: risk factor for paravalvular leakage.

نویسندگان

  • Borek Foldyna
  • Martin Hänsig
  • Christian Lücke
  • David Holzhey
  • Claudia Andres
  • Matthias Grothoff
  • Axel Linke
  • Friedrich Wilhelm Mohr
  • Matthias Gutberlet
  • Lukas Lehmkuhl
چکیده

BACKGROUND The aim of this study was to analyze the angle between the left ventricular (LV) long axis and the LV outflow tract (αLV-LVOT) on cardiac computed tomography and to describe its effect on the occurrence of paravalvular leakage (PL), fluoroscopy time, and postoperative creatine kinase-MB levels in transapical transcatheter aortic valve replacement (TA-TAVR). METHODS High-risk patients with severe aortic stenosis scheduled for TA-TAVR using an Edwards SAPIEN (Edwards Lifesciences, Irvine, CA) prosthesis were retrospectively included. The αLV-LVOT was measured during systole and diastole as far as retrospectively gated data sets were available. The αLV-LVOT was correlated with the occurrence of PL, total fluoroscopy time, and postoperative creatine kinase-MB levels. Interobserver variability was assessed in all cases. RESULTS The study included 81 patients (57 women [70.4%], 24 men [29.6%]) with an average age of 81.9±5.8 years. The mean αLV-LVOTs were 61.8±9.9 degrees during systole and 61.1±10.0 degrees during diastole. There was a minimal, nonsignificant change in the αLV-LVOT between systole and diastole of 0.2±4.1 degrees (p=0.7). PL was found in 39 patients: grade 0 in 42 (51.9%), grade I in 30 (37.0%), and grade II in 9 (11.1%). Patients with a clinically significant PL (grade≥II) showed a significantly greater mean αLV-LVOT than patients with grade I or without PL (mean difference, 13.8±3.2 degrees; p<0.001). No significant correlation was found between the αLV-LVOT and total fluoroscopy time (r=-0.17, p=0.16) and postoperative creatine kinase-MB levels (r=-0.1, p=0.44). CONCLUSIONS During TA-TAVR, greater αLV-LVOTs were associated with significantly higher grades of PL. Thus, the αLV-LVOT might influence the selection of the transapical implantation path and could have a significant effect on designs for future stents or novel delivery devices.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transapical Aortic Valve Implantation

Results Balloon redilation of the transcatheter valve was performed in 18 patients (5%), and additional second valves were implanted in 13 (4%). At the end of the procedure, 186 patients (52%) had no paravalvular or transvalvular regurgitation. In the remaining 172 patients, paravalvular leakage was observed in 113 (32%), transvalvular leakage in 47 (13%), and both in 12 (3%). Leakage was trace...

متن کامل

Transapical aortic valve implantation using a Symetis Acurate self-expandable bioprosthesis: initial outcomes of 10 patients

INTRODUCTION Transapical aortic valve implantation (TA-AVI) has been widely introduced for treatment of patients with severe aortic stenosis in the last decade. Here we report our first clinical experience with 10 patients using the second-generation transapical Symetis Acurate TA aortic valve designed for transapical implantation. AIM To evaluate the results of transapical access in transcat...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

Emergency transapical mitral valve-in-valve implantation for bioprosthesis failure: transapical implantation of an Edwards Sapien-XT in a dysfunctional mitral bioprosthesis in a critical patient

Background: Valve-in-Valve (VIV) Transcatheter Aortic Valve Replacement (TAVR) is now the treatment of choice in high-surgical-risk patients with failing aortic bioprosthesis. Although less performed, VIV-Transcatheter Mitral Valve Replacement (TMVR) is a valid treatment option for selected high-risk patients with degenerated mitral bioprostheses. Several cases of elective ViVTAVR and -TMVR hav...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Annals of thoracic surgery

دوره 98 5  شماره 

صفحات  -

تاریخ انتشار 2014