Imaging of lung ventilation and respiratory dynamics in a single ventilation cycle using hyperpolarized He-3 MRI.
نویسندگان
چکیده
PURPOSE To image respiratory dynamics and three-dimensional (3D) ventilation during inhalation, breath-hold, and exhalation for evaluation of obstructive lung disease using a single dose of hyperpolarized (HP) He-3 during MRI. MATERIALS AND METHODS A single 2D-3D projections inside Z encoding (PRIZE)-2D acquisition was performed that consisted of a rapid 2D radial acquisition phase during inhalation of the HP He-3, a 3D acquisition phase during a breath-hold interval, and finally the same 2D radial acquisition during a forced exhalation maneuver followed by tidal breathing. The 3D PRIZE acquisition was comprised of radial sampling in the coronal plane and Fourier encoding in the patient's anterior-posterior direction. Nine patients with mild/moderate to severe asthma were studied (two individuals were studied twice) using this technique. RESULTS Breath-hold and dynamic imaging results showed physiological abnormalities and were compared with results from standard spirometry, body plethysmography, and computed tomography (CT). Dynamic images depicted regions of differential gas clearance and trapping observed during and after forced exhalation that were corroborated as regions of air trapping on CT imaging. CONCLUSION The 2D-3D PRIZE-2D acquisition allowed for 3D depiction of ventilation during a breath-hold, as well as detection of gas trapping. Imaging results were confirmed with spirometry, body plethysmography, and CT.
منابع مشابه
Pulmonary ventilation visualized using hyperpolarized helium-3 and xenon-129 magnetic resonance imaging: differences in COPD and relationship to emphysema.
In subjects with chronic obstructive pulmonary disease (COPD), hyperpolarized xenon-129 ((129)Xe) magnetic resonance imaging (MRI) reveals significantly greater ventilation defects than hyperpolarized helium-3 ((3)He) MRI. The physiological and/or morphological determinants of ventilation defects and the differences observed between hyperpolarized (3)He and (129)Xe MRI are not yet understood. H...
متن کاملRapid imaging of hyperpolarized gas using EPI.
Rapid repetitive MRI of hyperpolarized (HP) gases using echo-planar imaging (EPI) has been theoretically investigated and experimentally demonstrated for (3)He in human lung. A quantitative treatment of signal attenuation and magnetization consumption for the unique circumstance of a rapidly diffusing nonrenewable magnetization source has been performed. Rapid (compared to the human respiratory...
متن کاملLinking Ventilation Heterogeneity Quantified via Hyperpolarized 3He MRI to Dynamic Lung Mechanics and Airway Hyperresponsiveness
Advancements in hyperpolarized helium-3 MRI (HP 3He-MRI) have introduced the ability to render and quantify ventilation patterns throughout the anatomic regions of the lung. The goal of this study was to establish how ventilation heterogeneity relates to the dynamic changes in mechanical lung function and airway hyperresponsiveness in asthmatic subjects. In four healthy and nine mild-to-moderat...
متن کاملImaging of lung function using hyperpolarized helium-3 magnetic resonance imaging: Review of current and emerging translational methods and applications.
During the past several years there has been extensive development and application of hyperpolarized helium-3 (HP (3)He) magnetic resonance imaging (MRI) in clinical respiratory indications such as asthma, chronic obstructive pulmonary disease, cystic fibrosis, radiation-induced lung injury, and transplantation. This review focuses on the state-of-the-art of HP (3)He MRI and its application to ...
متن کاملComparison of 3 He and 129 Xe MRI for evaluation of lung microstructure and ventilation at 1.5T.
BACKGROUND To support translational lung MRI research with hyperpolarized 129 Xe gas, comprehensive evaluation of derived quantitative lung function measures against established measures from 3 He MRI is required. Few comparative studies have been performed to date, only at 3T, and multisession repeatability of 129 Xe functional metrics have not been reported. PURPOSE/HYPOTHESIS To compare hy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 26 3 شماره
صفحات -
تاریخ انتشار 2007