Synthetic Quartz Crystal

ثبت نشده
چکیده

sq02_080825_terms_e Synthetic Quartz Crystal: A single crystal grown using the hydrothermal synthesis method. As-Grown Quartz Crystal: A synthetic quartz crystal grown naturally with no processing. Lumbered Quartz Crystal: A synthetic quartz crystal with the X and Z surfaces processed according to specified dimensions and angles using a diamond wheel #80. Y-bar Synthetic Quartz Crystal: A synthetic quartz crystal grown by using a bar-like seed crystal elongated in the Y-axis direction. Z-plate Synthetic Quartz Crystal: A synthetic quartz crystal grown by using a plate-like seed crystal with a Y-axis direction length and X-axis direction width. Inclusion: A general term for solid constituents (inclusions) that exist in synthetic quartz crystal; they can be observed when light is scattered through a liquid with a refractive index that is close to that of the synthetic quartz crystal. Main inclusions are acmite and emeleusite. They are generated by the chemical reaction of Fe within an autoclave and synthetic quartz crystal growth frame, Na from a solution, SiO2 of a material, etc. at high temperature and under high pressure. Twins: Crystallographically, taking into account specific facets or axes two or more crystals are symmetrically joined to one crystal. Almost all twin crystals that are generated as synthetic quartz crystals are electrical ones, and electrical twin crystals affect the shape of the synthetic quartz crystal. They can easily be identified visually. Right-handed and left-handed quartz crystals: Crystals are divided into two types: right-handed and left-handed. A difference in optical rotation creates the 2 types, but their physical properties are identical. Therefore, by cutting at the correct angle, the difference does not affect the characteristics of a crystal oscillator. Generally right-handed quartz crystals are used in manufacture. Zone: A zone with a crystal that has grown from a seed crystal at its core. There are Z, +X, -X, and S zones. Infrared Absorption Coefficient α: This value measured with an infrared spectrophotometer is adopted as the infrared absorption coefficient α of a synthetic quartz crystal. The value is based on the absorption characteristic of the OH radical of a synthetic quartz crystal that is around 3,800 to 3,000 cm–1 of the infrared transmittance curve. Generally, absorption coefficients with wave numbers 3585, 3500, and 3410 cm–1 have been adopted. (As is usual practice, an infrared Q value is also described for reference.) Etch Channel: Tubular cavities generated along linear defects in a crystal when the crystal is etched. When the processing of a crystal piece for manufacturing a tuning fork-type crystal oscillator or a reversed mesa-type involves etching, a synthetic quartz crystal with a low etch channel density is particularly suitable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct detection of calcium carbonate scaling via a pre-calcified sensitive area of a quartz crystal microbalance

In an industrial cooling circuit supplied with raw river water, the scaling phenomenon can reduce cooling efficiency and even lead to the shut down of the power plant. During the last twenty years, various methods have been developed in order to estimate the scaling propensity of natural waters, which involve the precipitation of calcium carbonate (CaCO3), the main component of scale. The FCP (...

متن کامل

Molecular Imprinting Technology in Quartz Crystal Microbalance (QCM) Sensors

Molecularly imprinted polymers (MIPs) as artificial antibodies have received considerable scientific attention in the past years in the field of (bio)sensors since they have unique features that distinguish them from natural antibodies such as robustness, multiple binding sites, low cost, facile preparation and high stability under extreme operation conditions (higher pH and temperature values,...

متن کامل

Biomimetic Yeast Cell Typing—Application of QCMs

Artificial antibodies represent a key factor in the generation of sensing systems for the selective detection of bioanalytes of variable sizes. With biomimetic surfaces, the important model organism Saccharomyces cerevisiae and several of its growth stages may be detected. Quartz crystal microbalances (QCM) with 10 MHz fundamental frequency and coated with polymers imprinted with synchronized y...

متن کامل

A Comparative Study of α-Hemolysin Expression in Supported Lipid Bilayers of Synthetic and Enriched Complex Bacterial Lipid

The purpose of this short communication was to examine whether the formation of a supported lipid bilayer (SLB) made with purely synthetic lipid or with Escherichia coli complex lipid may have any influence on the production and incorporation of the transmembrane protein α-hemolysin from Staphylococcus. Different molar ratio of E. coli total extract lipid and synthetic 1-palmitoyl-2-oleoyl-sn-g...

متن کامل

Design and Fabrication of a Quartz Crystal Resonator Used in a Thickness-Monitor Unit (TECHNICAL NOTES).

This paper deals with the design and fabrication of a quartz-crystal resonator used in a thickness-monitor unit, measuring film thickness in a film-depositing system. A purpose-grown quartz crystal is cut to form the desired wafer. Two gold electrodes are deposited on both surfaces of the wafer to provide electrical contacts. The resonance frequency of the resonator, at room temperature, and th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008