Monitoring of ethylene by a pulsed quantum cascade laser.

نویسندگان

  • Damien Weidmann
  • Anatoliy A Kosterev
  • Chad Roller
  • Robert F Curl
  • Matthew P Fraser
  • Frank K Tittel
چکیده

We report on the development and performance of a gas sensor based on a quantum cascade laser operating at a wavelength of approximately 10 microns to measure ethylene (C2H4) concentrations by use of a rotational component of the fundamental nu 7 band. The laser is thermoelectrically cooled and operates in a pulsed mode. The influence of pulse-to-pulse fluctuations is minimized by use of a reference beam and a single detector with time discriminating electronics. Gas absorption is recorded in a 100-m optical path-length astigmatic Herriott cell. With a 10-kHz pulse repetition rate and an 80-s total acquisition time, a noise equivalent sensitivity of 30 parts per billion has been demonstrated. The sensor has been applied to monitor C2H4 in vehicle exhaust as well as in air collected in a high-traffic urban tunnel.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Effective Parameters on Pulsed Nd:YAG Passive Q-Switched Laser

In this paper, we report the experimental results of a pulsed flash lamped Nd:YAG laser at wavelength of 1064 nm and Qswitched by Cr4+:YAG solid state saturable absorber. We have obtained the output energy (E) and pulse-width ( p τ ) of this laser for various initial transmissions of this saturable absorber. Furthermore, the effect of reflectivity of the output coupler (R), diameter of the rod ...

متن کامل

Ethylene spectroscopy using a quasi-room-temperature quantum cascade laser.

Spectroscopic measurements on ethylene were performed using a quasi-room-temperature quantum cascade (QC) laser operated in pulsed mode in the 10.3 microm range. Using transmission spectroscopy, a broadening of the ethylene absorption spectrum was observed with increasing laser pulse duration, due to an increase of the laser linewidth. This linewidth was determined from the measured absorption ...

متن کامل

Sensitivity enhancement in off-axis integrated cavity output spectroscopy.

We report on a detailed model of an improved three mirror off-axis integrated cavity output spectroscopy (OA-ICOS) setup, which re-injects the light reflected by the optical cavity. The model simulates the impact of design parameters on instrument sensitivity and can be used for any off-axis configuration. We demonstrate the application of this model for the real-time detection of ethylene with...

متن کامل

Temperature Effect on THz Quantum Cascade Lasers

A simple semi-phenomenological model, which accurately predicts the dependence of thresholdcurrent for temperature of Resonant-phonon three well quantum cascade laser based on verticaltransitions is offered. We found that, the longitude optical phonon scattering of thermally excitedelectrons is the most important limiting factor for thermal performance of high frequency THz QCLs.In low frequenc...

متن کامل

Thermal Conductivity of Reduced Graphene Oxide by Pulse Laser in Ethylene Glycol

Graphene oxide was prepared using modified Hummers method. Stable ethylene-glycol nanofluids containing graphene oxide nanosheets were provided. Nd: YAG pulsed laser was applied to prepare reduced nanofluids. Experimental results revealed that thermal conductivity of the nanofluids is increased with increasing the concentration of graphene oxide (GO) in ethylene glycol. The enhancement ratio of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 43 16  شماره 

صفحات  -

تاریخ انتشار 2004