A comparison between several acetylcholinesterase (AChE) immobilization procedures on the 7,7,8,8-tetracyanoquinodimethane (TCNQ)modified graphite working electrodes is presented. The immobilization methods employed crosslinking with glutaraldehyde in presence of BSA protein and photopolymerization with poly(vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ). The main variations were related to the enzyme charge in each electrode and the enzyme conditioning and storage conditions after immobilization. Initially, the enzyme–substrate reaction was carried out and the following parameters were chrono-amperometrically and -coulometrically monitored: current intensities, time to stabilize the current response, and the mass transfer represented by the Coulomb charge. The screen-printed biosensors that presented best characteristics were then used to perform the inhibition assays and to verify the sensitivity against the following NMC insecticides: aldicarb, carbaryl, carbofuran, and methomyl. In general, diffusion of electrons into the sensitive layer, mass transfer, and time to stabilize the current were adequate in all cases. The Cottrell law was followed before the 1 min of enzyme–substrate reaction. Adequate reproducibility within electrochemical measurements was also observed, with relative standard deviations varying from 6.5 to 18.6%. AChE immobilization with glutaraldehyde allow to obtain robust and reproducible biosensors, but they need a much higher enzyme content (80 mUA per electrode) to achieve current values comparable to that constructed by immobilizing the AChE through photopolymerization with PVA-SbQ (0.7 to 1 mUA per electrode). The limits of detection were determined with a minimum 10% inhibition, and varied from 10−9 to 8 × 10−9 M (0.2 to 1.5 ppb) by employing the enzyme immobilization through photopolymerization with PVA-SbQ. In practice, this kind of immobilization procedure is much simpler and produces good results: fast response, adequate reproducibility, large pesticides working ranges, and excellent sensitivities to N-methylcarbamates (NMCs) which in general do not present enzyme inhibition power as elevated as for the organophosphate pesticides. © 2004 Elsevier B.V. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of carbamic and organophosphorous pesticides in water samples using a cholinesterase biosensor based on Prussian Blue-modified screen-printed electrode.

In the present paper, a comparative study using Co-phthalocyanine and Prussian Blue-modified screen-printed electrodes, has been performed. Both the electrodes have demonstrated an easiness of preparation together with high sensitivity towards thicoholine (LOD=5 x 10(-7) and 5 x 10(-6) M for Co-phthalocyanine and Prussian Blue, respectively) with high potentialities for pesticide measurement. P...

متن کامل

Cholinesterase sensors based on screen-printed electrodes for detection of organophosphorus and carbamic pesticides.

Cholinesterase sensors based on screen-printed electrodes modified with polyaniline, 7,7',8,8'-tetracyanoquinodimethane (TCNQ), and Prussian blue have been developed and tested for detection of anticholinesterase pesticides in aqueous solution and in spiked grape juice. The influence of enzyme source and detection mode on biosensor performance was explored. It was shown that modification of the...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Biosensors designed for environmental and food quality control based on screen-printed graphite electrodes with different configurations.

Graphite electrodes fabricated by screen-printing have been used as amperometric detectors in biosensors based on NAD(+)-dependent dehydrogenases, tyrosinase, or genetically modified acetylcholinesterases. The mono-enzyme sensors have been optimized as disposable or reusable devices for detection of a variety of substrates important in the food industry ( D-lactic acid, L-lactic acid, acetaldeh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004