Nonaqueous reversed-phase liquid chromatography and fluorimetry compared for determination of retinol in serum.
نویسندگان
چکیده
A new assay for retinol in human serum, based on nonaqueous reversed-phase liquid chromatography, is presented. Sample preparation includes addition of the internal standard, retinyl propionate, deproteinization of 100 microL of serum with acetonitrile, and extraction with hexane. The standard curve is linear up to 2 mg/L. The assay is characterized by excellent sensitivity (detection limit, 15 micrograms/L) and good within-run and between-run precision (CVs of 2.6 and 2.7%, respectively), and results compare favorably with those by fluorimetry. We assayed 135 samples from hospitalized patients by both methods. Although the two sets of values correlated well (r = 0.955) the fluorimetric method occasionally suffers from interferences. In practice, fluorimetry proves valuable as a routine method, while liquid chromatography meets the criteria of a potential reference method.
منابع مشابه
Reversed-phase Salt Assisted Liquid-liquid Extraction: A New Technique for Preconcentration and Determination of Crocin in Herbal Medicines by HPLC
A reversed-phase salt assisted liquid-liquid extraction (RP-SALLE) method was developed for the preconcentration and determination of trace crocin in herbal medicines by high-performance liquid chromatography (HPLC). In developed method, the roles of the aqueous and organic phases are inverted so that the analyte is extracted from the organic into the aqueous phase after salt addition and phase...
متن کاملA simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples
Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55...
متن کاملبکارگیری کروماتوگرافی مایع با کارکرد بالا
World health organization has introduced concentration of vitamin A in breast milk as a proper indicator for characterization of vitamin A deficiency in lactating mothers and their infants (<6 mo). A normal phase high performance liquid chromatography with spectrofluorometric detection as a specific and sensitive detector was used for characterization of all-trans retional from 13-Cis retinal. ...
متن کاملSimultaneous determination of retinol and retinyl esters in serum or plasma by reversed-phase high-performance liquid chromatography.
We propose a single-run liquid-chromatographic determination, with ultraviolet detection at 330 nm, for serum retinol and retinyl esters. The vitamin A derivatives are extracted according to the Bligh-Dyer procedure. With 200 microliter or serum, the lower detection limit is 50 microgram/liter for retinol and about 100 microgram/liter for retinyl esters. Within-run precision (CV) was 2.3% for r...
متن کاملHigh Performance Liquid Chromatography Determination of Sertraline in Human
An accurate and sensitive reversed-phase high-performance liquid chromatograph-ic method for determination of sertraline in human serum is described using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent. The drug and an internal standard (azithrimycin) were extracted from serum using a mixture of diethyl ether-chloroform and subjected to the pre-column derivatization with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 29 7 شماره
صفحات -
تاریخ انتشار 1983