A comparison of FreeSurfer-generated data with and without manual intervention

نویسندگان

  • Christopher S. McCarthy
  • Avinash Ramprashad
  • Carlie Thompson
  • Jo-Anna Botti
  • Ioana L. Coman
  • Wendy R. Kates
چکیده

This paper examined whether FreeSurfer-generated data differed between a fully-automated, unedited pipeline and an edited pipeline that included the application of control points to correct errors in white matter segmentation. In a sample of 30 individuals, we compared the summary statistics of surface area, white matter volumes, and cortical thickness derived from edited and unedited datasets for the 34 regions of interest (ROIs) that FreeSurfer (FS) generates. To determine whether applying control points would alter the detection of significant differences between patient and typical groups, effect sizes between edited and unedited conditions in individuals with the genetic disorder, 22q11.2 deletion syndrome (22q11DS) were compared to neurotypical controls. Analyses were conducted with data that were generated from both a 1.5 tesla and a 3 tesla scanner. For 1.5 tesla data, mean area, volume, and thickness measures did not differ significantly between edited and unedited regions, with the exception of rostral anterior cingulate thickness, lateral orbitofrontal white matter, superior parietal white matter, and precentral gyral thickness. Results were similar for surface area and white matter volumes generated from the 3 tesla scanner. For cortical thickness measures however, seven edited ROI measures, primarily in frontal and temporal regions, differed significantly from their unedited counterparts, and three additional ROI measures approached significance. Mean effect sizes for edited ROIs did not differ from most unedited ROIs for either 1.5 or 3 tesla data. Taken together, these results suggest that although the application of control points may increase the validity of intensity normalization and, ultimately, segmentation, it may not affect the final, extracted metrics that FS generates. Potential exceptions to and limitations of these conclusions are discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Parametric surface modeling and registration for comparison of manual and automated segmentation of the hippocampus.

Accurate and efficient segmentation of the hippocampus from brain images is a challenging issue. Although experienced anatomic tracers can be reliable, manual segmentation is a time consuming process and may not be feasible for large-scale neuroimaging studies. In this article, we compare an automated method, FreeSurfer (V4), with a published manual protocol on the determination of hippocampal ...

متن کامل

Comparing manual and automatic segmentation of hippocampal volumes: reliability and validity issues in younger and older brains.

We compared hippocampal volume measures obtained by manual tracing to automatic segmentation with FreeSurfer in 44 younger (20-30 years) and 47 older (60-70 years) adults, each measured with magnetic resonance imaging (MRI) over three successive time points, separated by four months. Retest correlations over time were very high for both manual and FreeSurfer segmentations. With FreeSurfer, corr...

متن کامل

FreeSurfer-initiated fully-automated subcortical brain segmentation in MRI using Large Deformation Diffeomorphic Metric Mapping

Fully-automated brain segmentation methods have not been widely adopted for clinical use because of issues related to reliability, accuracy, and limitations of delineation protocol. By combining the probabilistic-based FreeSurfer (FS) method with the Large Deformation Diffeomorphic Metric Mapping (LDDMM)-based label-propagation method, we are able to increase reliability and accuracy, and allow...

متن کامل

Quantitative Comparison of Two Cortical Surface Extraction Methods Using MRI Phantoms

In the last decade several methods for extracting the human cerebral cortex from magnetic resonance images have been proposed. Studies comparing these methods have been few. In this study we compare a recent cortical extraction method with FreeSurfer, which has been widespread in the scientific community during recent years. The comparison is performed using realistic phantoms generated from su...

متن کامل

Automatic hippocampal segmentation in temporal lobe epilepsy: Impact of developmental abnormalities

In drug-resistant temporal lobe epilepsy (TLE), detecting hippocampal atrophy on MRI is important as it allows defining the surgical target. The performance of automatic segmentation in TLE has so far been considered unsatisfactory. In addition to atrophy, about 40% of patients present with developmental abnormalities (referred to as malrotation) characterized by atypical morphologies of the hi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015