Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies.
نویسندگان
چکیده
Image inhomogeneity related to high radiofrequencies is one of the major challenges for high field imaging. This inhomogeneity can be thought of as having 2 radiofrequency-field related contributors: the transmit field distribution and the reception field distribution. Adjusting magnitude and phase of currents in elements of a transmit array can significantly improve flip angle homogeneity at high field. Effective application of some well-known parallel imaging and other receive array post-processing methods removes receptivity patterns from the intensity distribution in the final image, though noise then becomes a function of position in the final image. Here simulations are used to show that, assuming high signal-to-noise ratio, very homogeneous images in the human head can be acquired with the combination of transmit arrays and some receive array reconstruction methods at frequencies as high as 600 MHz.
منابع مشابه
SVD based calibration of transmit arrays
Introduction: In order to optimally combine signals received from an array coil, the sensitivities of each element have to be known. Acquiring these receive sensitivities is especially challenging at ultra high field conditions using transmit-receive arrays (TRA), since signal voids induced by destructive interferences of the transmit B1 fields cause strong local noise amplification in the obta...
متن کاملA 16-Channel Receive, Forced Current Excitation Dual-Transmit Coil for Breast Imaging at 7T
PURPOSE To enable high spatial and temporal breast imaging resolution via combined use of high field MRI, array coils, and forced current excitation (FCE) multi channel transmit. MATERIALS AND METHODS A unilateral 16-channel receive array insert was designed for use in a transmit volume coil optimized for quadrature operation with dual-transmit RF shimming at 7 T. Signal-to-noise ratio (SNR) ...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملArray-optimized composite pulse for excellent whole-brain homogeneity in high-field MRI.
A number of methods to improve excitation homogeneity in high-field MRI have been proposed, and some of these methods rely on separate control of radiofrequency (RF) coils in a transmit array. In this work we combine accurate RF field calculations and the Bloch equation to demonstrate that by using a sequence of pulses with individually optimized current distributions (i.e., an array-optimized ...
متن کاملParallel transmit and receive technology in high-field magnetic resonance neuroimaging
The major radiofrequency engineering challenges of high-field MR neuroimaging are as follows: (1) to produce a strong, homogeneous transmit B1 field, while remaining within regulatory guidelines for tissue power deposition and (2) to receive the signal with the maximum signal-to-noise and the greatest flexibility in terms of utilizing the benefits of parallel imaging. Borrowing from development...