Exertion Does Not Affect the Optic Nerve Sheath Diameter in Healthy Participants

نویسندگان

  • Kyle Friez
  • Matthew Lyon
  • Ivan A. Morales
  • Ann Marie Kuchinski
  • Hongyan Xu
  • Richard Gordon
چکیده

The purpose of this study was to determine if exertion influences the ONSD in healthy individuals. Healthy adults were eligible for inclusion. Activities were performed by each participant for 60 seconds and were as follows: sprinting, holding a 10-pound weight with both arms outstretched parallel to the floor, a Valsalva maneuver, a plank position, and positioning the head down thirty degrees with the participant in the supine position. Two-dimensional ultrasound images visualizing the optic nerve sheath (ONS) were recorded in three orientations and averaged to determine the mean ONSD 3 millimeters posterior to the retina. Baseline measurements ranged from 3.57 to 4.90 millimeters. Post-exertion measurements ranged from 3.60 to 4.93 millimeters. Based on a one sample paired t-test the difference between baseline and post-activity measurements were not significant. This study demonstrates that ONSD measurements by ultrasound do not change in healthy individuals in response to exertion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of scuba-diving on optic nerve and sheath diameters

  Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated.   Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...

متن کامل

Comparative study measuring optic nerve sheath diameter by transorbital ultrasound in healthy women, pregnant women and pregnant with preeclampsia / eclampsia

Introduction Preeclampsia / eclampsia is a potentially serious disease associated with maternal complications, including neurological. In patients with increased intracranial pressure, the diameter of the optic nerve sheath increases because of its close association with the flow of cerebrospinal fluid. Her measurements using ultrasound transorbital have shown correlation with increased intracr...

متن کامل

Transorbital sonography in acute optic neuritis: a case-control study.

BACKGROUND AND PURPOSE Acute unilateral optic neuritis is associated with a thickening of the retrobulbar portion of the optic nerve as revealed by transorbital sonography, but no comparison has been made between nerve sheath diameter and optic nerve diameter in patients with acute optic neuritis versus healthy controls. We evaluated optic nerve sheath diameter and optic nerve diameter in patie...

متن کامل

Coronal Axis Measurement of the Optic Nerve Sheath Diameter.

OBJECTIVES The true optic nerve sheath diameter cutoff value for detecting elevated intracranial pressure is variable. The variability may stem from the technique used to acquire sonographic measurements of the optic nerve sheath diameter as well as sonographic artifacts inherent to the technique. The purpose of this study was to compare the traditional visual axis technique to an infraorbital ...

متن کامل

Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults

BACKGROUND Measurement of optic nerve sheath diameter (ONSD) is a fast and non-invasive method in detecting elevated intracranial pressure. However, the reported normal range of ONSD was inconsistent. The objective of the study was to determine the normal range of ONSD in healthy Chinese adults. METHODS Eyeball transverse diameter (ETD), optic nerve diameter (OND), and ONSD were measured by u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016