Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for 90Y microsphere selective internal radiation therapy

نویسندگان

  • Justin K Mikell
  • Armeen Mahvash
  • Wendy Siman
  • Firas Mourtada
  • S Cheenu Kappadath
چکیده

BACKGROUND To assess differences between four different voxel-based dosimetry methods (VBDM) for tumor, liver, and lung absorbed doses following (90)Y microsphere selective internal radiation therapy (SIRT) based on (90)Y bremsstrahlung SPECT/CT, a secondary objective was to estimate the sensitivity of liver and lung absorbed doses due to differences in organ segmentation near the liver-lung interface. METHODS Investigated VBDM were Monte Carlo (MC), soft-tissue kernel with density correction (SKD), soft-tissue kernel (SK), and local deposition (LD). Seventeen SIRT cases were analyzed. Mean absorbed doses ([Formula: see text]) were calculated for tumor, non-tumoral liver (NL), and right lung (RL). Simulations with various SPECT spatial resolutions (FHWMs) and multiple lung shunt fractions (LSs) estimated the accuracy of VBDM at the liver-lung interface. Sensitivity of patient RL and NL [Formula: see text] on segmentation near the interface was assessed by excluding portions near the interface. RESULTS SKD, SK, and LD were within 5 % of MC for tumor and NL [Formula: see text]. LD and SKD overestimated RL [Formula: see text] compared to MC on average by 17 and 20 %, respectively; SK underestimated RL [Formula: see text] on average by -60 %. Simulations (20 mm FWHM, 20 % LS) showed that SKD, LD, and MC were within 10 % of the truth deep (>39 mm) in the lung; SK significantly underestimated the absorbed dose deep in the lung by approximately -70 %. All VBDM were within 10 % of truth deep (>12 mm) in the liver. Excluding 1, 2, and 3 cm of RL near the interface changed the resulting RL [Formula: see text] by -22, -38, and -48 %, respectively, for all VBDM. An average change of -7 % in the NL [Formula: see text] was realized when excluding 3 cm of NL from the interface. [Formula: see text] was realized when excluding 3 cm of NL from the interface. CONCLUSIONS SKD, SK, and LD are equivalent to MC for tumor and NL [Formula: see text]. SK underestimates RL [Formula: see text] relative to MC whereas LD and SKD overestimate. RL [Formula: see text] is strongly influenced by the liver-lung interface.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changing Therapeutic Paradigms: Predicting mCRC Lesion Response to Selective Internal Radionuclide Therapy (SIRT) based on Critical Absorbed Dose Thresholds: A Case Study

A 65 year old male with metastatic colorectal cancer (mCRC) in the liver was referred for selective internal radionuclide therapy (SIRT) following a history of extensive systemic chemotherapy. 90Y PET imaging was performed immediately after treatment and used to confirm lesion targeting and measure individual lesion absorbed doses. Lesion dosimetry was highly predictive of eventual response in ...

متن کامل

Dosimetry of Nano-Radio-Ytterbium Therapy by MIRD and MCNP methods for humans’ organs

Introduction: Nano radio-pharmaceutical therapy (NRPT) is a new method for solid tumor therapy. The treatment uses a radioactive form of radionuclide encapsulated in the poly amido amine dendrimers. The poly (amidoamine) (PAMAM) dendrimers have attracted attentions for cancer treatment by their characteristics of targeted drug carriers, delivery agents, and imaging agents in hu...

متن کامل

PET/CT-Based Dosimetry in 90Y-Microsphere Selective Internal Radiation Therapy: Single Cohort Comparison With Pretreatment Planning on 99mTc-MAA Imaging and Correlation With Treatment Efficacy

⁹⁰Y PET/CT can be acquired after ⁹⁰Y-microsphere selective radiation internal therapy (SIRT) to describe radioactivity distribution. We performed dosimetry using ⁹⁰Y-microsphere PET/CT data to evaluate treatment efficacy and appropriateness of activity planning from (99m)Tc-MAA scan and SPECT/CT. Twenty-three patients with liver malignancy were included in the study. (99m)Tc-MAA was injected du...

متن کامل

Evaluating the Application of Tissue-Specific Dose Kernels Instead of Water Dose Kernels in Internal Dosimetry: A Monte Carlo Study.

PURPOSE The aim of this work is to evaluate the application of tissue-specific dose kernels instead of water dose kernels to improve the accuracy of patient-specific dosimetry by taking tissue heterogeneities into consideration. MATERIALS AND METHODS Tissue-specific dose point kernels (DPKs) and dose voxel kernels (DVKs) for yttrium-90 (90Y), lutetium-177 (177Lu), and phosphorus-32 (32P) are ...

متن کامل

A CVH-based computational female pelvic phantom for radiation dosimetry simulation

Background: Accurate voxel phantom is needed for dosimetric simulation in radiation therapy for malignant tumors in female pelvic region. However, most of the existing voxel phantoms are constructed on the basis of Caucasian or non-Chinese population. Materials and Methods: A computational framework for constructing female pelvic voxel phantom for radiation dosimetry was performed base...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015