Assessment of human long saphenous vein function with minimally invasive harvesting with the Mayo stripper.

نویسندگان

  • D J O'Regan
  • J A Borland
  • A H Chester
  • D J Pennell
  • M Yacoub
  • J R Pepper
چکیده

BACKGROUND The use of the Mayo Stripper to harvest the long saphenous vein has been shown to improve morbidity from leg wound incisions. It has not been universally accepted because of a perceived increase in injury to the venous conduit. OBJECTIVE To compare the function of undistended autologous long saphenous vein harvested by a Mayo stripper with the traditional 'open' technique in the same patient (n = 12) appearance. METHODS Vascular reactivity was assessed in isolated organ baths. Contractile function was measured in response to increasing concentrations (10(-9)-10(-5) mol) of 5-hydroxytryptamine and noradrenaline. This was calculated as a percentage of the maximum contractile response to 90 mM KCl measured in millinewtons (mN) (control 41.4 +/- 12.1, (n = 11), open technique 35.8 +/- 11.1, (n = 11), Mayo stripper 33.7 +/- 15.9, (n = 11)). The endothelial dependent and independent function was assessed with acetylcholine and sodium nitroprusside, respectively. RESULTS There was no significant difference in response to both constrictors and dilators between vein taken with the Mayo stripper compared with the traditional open technique (n = 6 for each observation; P > 0.05 by ANOVA). Histological examination by light microscopy of the vessel segments removed with the Mayo stripper was unable to show any significant damage to the vessel wall. Both functional and morphological studies were conducted by 'blinded' observers. One-year follow-up with magnetic resonance angiography (MRA) and stress thallium tomography demonstrated a patency rate with lower and upper estimates of 80 and 94%. CONCLUSIONS We have shown that harvesting the long saphenous vein with a Mayo stripper does not compromise vascular reactivity of the long saphenous vein or long-term patency.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decreased morbidity following long saphenous vein harvesting using a minimally invasive technique: a randomised controlled trial comparing two techniques for long saphenous vein harvest

OBJECTIVES The objective of this study was to compare the morbidity associated with long saphenous vein harvesting using the traditional open technique (A) against a minimally invasive technique using the Mayo vein stripper (B) that involves multiple short incisions. DESIGN We conducted a prospective randomized controlled study in 80 patients undergoing first time coronary artery bypass graft...

متن کامل

Comparison of therapeutic results of large saphenous vein resection with conventional methods and standard bridging

                                                                 Background: The use of the traditional method for saphenous vein harvesting is associated with wound complications and not on-time patient mobilization. This has caused the improvement of minimally invasive vein harvesting techniques, together with general bridging. This study was designed to compare the therapeutic results of...

متن کامل

Minimally invasive saphenous vein harvesting for coronary artery bypass grafting--comparison of three less invasive methods.

INTRODUCTION Saphenous vein is routinely harvested using one or a few long continuous skin incisions. This method is associated with typical healing complications such as oedemas, pain, necrosis, what often restricts proper rehabilitation. An alternative minimally invasive techniques may decrease these complications. MATERIAL AND METHODS This prospective randomised trial compared outcomes ass...

متن کامل

Necrotizing Fasciitis Following Endoscopic Harvesting of the Greater Saphenous Vein for Coronary Artery Bypass Graft

The greater saphenous vein (GSV) remains the most commonly harvested conduit for revascularization in coronary artery bypass grafting (CABG). Published literature shows that minimally invasive vein harvesting techniques have a significantly lower incidence of wound infection rates than conventional open vein harvesting techniques have. We report a case of necrotizing fasciitis, an infection wit...

متن کامل

"Over-the-wire" inversion saphenectomy: a simple, minimally invasive vein harvesting technique for arterial bypass.

PURPOSE To examine the feasibility and clinical outcome of a novel, minimally invasive technique for harvesting the great saphenous vein (GSV) for use in peripheral arterial bypass surgery. METHODS Between May 2001 through March 2003, 27 patients (15 men; mean age 71+/-10 years) underwent extremity bypass procedures for limb salvage (88%) or disabling claudication (12%) using the inversion te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 12 3  شماره 

صفحات  -

تاریخ انتشار 1997