Influence of heat transfer with tube methods on measured thermal inactivation parameters for Escherichia coli.

نویسندگان

  • Hyun-Jung Chung
  • Shaojin Wang
  • Juming Tang
چکیده

The purpose of this study was to investigate the influence of heat transfer on measured thermal inactivation kinetic parameters of bacteria in solid foods when using tube methods. The bacterial strain selected for this study, Escherichia coli K-12, had demonstrated typical first-order inactivation characteristics under isothermal test conditions. Three tubes of different sizes (3, 13, and 20 mm outer diameter) were used in the heat treatments at 57, 60, and 63 degrees C with mashed potato as the test food. A computer model was developed to evaluate the effect of transit heat transfer behavior on microbial inactivation in the test tubes. The results confirmed that the survival curves of E. coli K-12 obtained in 3-mm capillary tubes were log linear at the three tested temperatures. The survival curves observed under nonisothermal conditions in larger tubes were no longer log linear. Slow heat transfer alone could only partially account for the large departures from log-linear behavior. Tests with the same bacterial strain after 5 min of preconditioning at a sublethal temperature of 45 degrees C revealed significantly enhanced heat resistance. Confirmative tests revealed that the increased heat resistance of the test bacterium in the center of the large tubes during the warming-up periods resulted in significantly larger D-values than those obtained with capillary tube methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Tube Arrangement on the Thermal Performance of Indirect Water Bath Heaters

Natural convection heat transfer from a tube bundle in the indirect water bath heaters is investigated. A computer-code is used for the solution of the governing equations of mass, momentum and energy transfer based on the SIMPLE-C algorithm. Simulations are carried out for the gas pressure station heater of Kermanshah city with various tube bundle arrangements. In order to validate the numeric...

متن کامل

Analysis of variance of nanofluid heat transfer data for forced convection in horizontal spirally coiled tubes

In the present study, an experimental study is carried out to investigate the effect of adding Al and Cu nanoparticles to the base fluid (water) on the heat transfer rate in a spirally coiled tube. The spirally coiled tube is fabricated from the straight copper tube with the inner and outer coil diameters of 100 and 420 mm, respectively. The experiments have been done for water and two types of...

متن کامل

Investigation on Escherichia Coli Inactivation and Some Quality Changes in Carrot Juice by Ultrasound Technique

In this study Response Surface Methodology was used to optimize process conditions and to evaluate the effect of ultrasound on quality attributes (antioxidant activity, pH, total soluble solid, turbidity) and the inactivation of Escherichia coli bacteria in carrot juice. Independent variables in this study were temperature (25-50°C), time (20-40 min) and frequency (0-130 kHz). In this study the...

متن کامل

The Overall Heat Transfer Characteristics of a Double Pipe Heat Exchanger: Comparison of Experimental Data with Predictions of Standard Correlations

The single-phase flow and thermal performance of a double pipe heat exchanger are examined by experimental methods. The working fluid is water at atmospheric pressure. Temperature measurements at the inlet and outlet of the two streams and also at an intermediate point half way between the inlet and outlet is made, using copper-constantan thermocouple wires. Mass flow rates for each stream are ...

متن کامل

Investigation on Escherichia Coli Inactivation and Some Quality Changes in Carrot Juice by Ultrasound Technique

In this study Response Surface Methodology was used to optimize process conditions and to evaluate the effect of ultrasound on quality attributes (antioxidant activity, pH, total soluble solid, turbidity) and the inactivation of Escherichia coli bacteria in carrot juice. Independent variables in this study were temperature (25-50°C), time (20-40 min) and frequency (0-130 kHz). In this study the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of food protection

دوره 70 4  شماره 

صفحات  -

تاریخ انتشار 2007