Fatigue failure of cortical bone screws.

نویسندگان

  • M S Zand
  • S A Goldstein
  • L S Matthews
چکیده

An experimental study of the fatigue life of cortical bone screws under conditions which stimulated in vivo usage was performed. The two most important factors influencing fatigue life were axial screw tension (the force normal of the plate to bone) and the cyclic shearing load. All screws failed at the root of the thread in the interface between the plate and the bone. A modified screw design effectively resisted fatigue under the described experimental conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis

Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...

متن کامل

Fatigue Performance of Cortical Bone Trajectory Screw Compared With Standard Trajectory Pedicle Screw.

STUDY DESIGN Cadaveric biomechanical study. OBJECTIVE To determine fatigue behavior of cortical bone trajectory (CBT) pedicle screws. SUMMARY OF BACKGROUND DATA Cortical bone trajectory screws have been becoming popular in spine surgery; however, the long-term fatigue behavior of the new CBT screws remains understudied and limitations not well defined. METHODS Twelve vertebrae from six ca...

متن کامل

Cancellous Screws Are Biomechanically Superior to Cortical Screws in Metaphyseal Bone.

Cancellous screws are designed to optimize fixation in metaphyseal bone environments; however, certain clinical situations may require the substitution of cortical screws for use in cancellous bone, such as anatomic constraints, fragment size, or available instrumentation. This study compares the biomechanical properties of commercially available cortical and cancellous screw designs in a synth...

متن کامل

Cortical bone trajectory for lumbar pedicle screws.

BACKGROUND CONTEXT Achieving solid implant fixation to osteoporotic bone presents a clinical challenge. New techniques and devices are being designed to increase screw-bone purchase of pedicle screws in the lumbar spine via a novel cortical bone trajectory that may improve holding screw strength and minimize loosening. Preliminary clinical evidence suggests that this new trajectory provides scr...

متن کامل

Biomechanical comparison of axial load between cannulated locking screws and noncannulated cortical locking screws.

The goal of this study was to compare the biomechanical stability of cannulated locking screws and noncannulated cortical locking screws in a periarticular locking plate. Twelve fresh-frozen porcine tibias with a 1-cm gap created distal to the tibial plateau were used to simulate an unstable proximal tibial fracture. All specimens were fixed with a periarticular proximal lateral tibial locking ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 16 5  شماره 

صفحات  -

تاریخ انتشار 1983