Comparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study.
نویسندگان
چکیده
BACKGROUND Dimensional accuracy when making impressions is crucial to the quality of fixed prosthodontic treatment, and the impression technique is a critical factor affecting this accuracy. The purpose of this in vitro study was to compare the dimensional accuracy of the casts obtained from one step double mix, two step double mix polyvinyl siloxane putty- wash impression techniques using three different spacer thicknesses (0.5mm, 1mm and 1.5mm), in order to determine the impression technique that displays the maximum linear dimensional accuracy. MATERIALS & METHODS A Mild steel model with 2 abutment preparations was fabricated, and impressions were made 15 times with each technique. All impressions were made with an addition-reaction silicone impression material (Express, 3M ESPE) and customarily made perforated metal trays. The 1-step putty/light-body impressions were made with simultaneous use of putty and light-body materials. The 2-step putty/light-body impressions were made with 0.5-mm, 1mm and 1.5mm-thick metal-prefabricated spacer caps. The accuracy of the 4 different impression techniques was assessed by measuring 7 dimensions (intra- and inter abutment) (20-μm accuracy) on stone casts poured from the impressions of the mild steel model. The data were analyzed by one sample't' test. RESULTS The stone dies obtained with all the techniques had significantly larger or smaller dimensions as compared to those of the mild steel model (P<0.05). The order for highest to lowest deviation from the mild steel model was: single step putty/light body, 2-step putty/light body with 0.5mm spacer thickness, 2-step putty/light body1.5mm spacer thickness, and 2-step putty/light body with 1mm spacer thickness. Significant differences among all of the groups for both absolute dimensions of the stone dies, and their standard deviations from the master model (P<0.05), were noted. CONCLUSIONS The 2-step putty/light-body impression technique with 1mm spacer thickness was most dimensionally accurate impression methods in terms of resultant casts. How to cite this article: Dugal R, Railkar B, Musani S. Dimensional accuracy when making impressions is crucial to the quality of fixed prosthodontic treatment, and the impression technique is a critical factor affecting this accuracy. J Int Oral Health 2013;5(5):85-94.
منابع مشابه
Comparative Analysis of Dimensional Accuracy of Two Types of Silicone Impression Materials: Optosil and Elite-HD
Statement of the Problem: Understanding about impression materials, their properties, uses and manipulation can guide operators towards having more successful restorations. Purpose: The aim of this in vitro study was to compare the accuracy of a condensation silicone impression material, Optosil, and an addition poly siloxane impression material, Elite-HD. Materials and Method: A laboratory mod...
متن کاملDimensional Accuracy of Polyvinyl Siloxane Impression Materials Considering Impression Techniques– A Literature Review
Objectives Impression accuracy is the main determinant of the fit, form and function of prosthetic restorations. Polyvinyl siloxane (PVS) is the material of choice in most clinical situations. The purpose of this paper is to provide an up-to-date review of scientific articles which discuss the dimensional accuracy of PVS impression material using various impression techniques, tray types and sp...
متن کاملComparative Evaluation of the Dimensional Accuracy of Different Putty-Wash Techniques Using Additional Silicon Impression Material In Vitro Study
Purpose: The aim of the present study was to evaluate and compare the dimensional accuracy of stone models made by addition silicone impression material using three puttywash impression techniques: one step putty wash (dual viscosity), two step and modified two step putty wash technique. Material and Methods: A stainless steel master model was constructed simulating a three-unit fixed prosthesi...
متن کاملDimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study
Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...
متن کاملEffects of Rewash on the Accuracy of Stone Dies Produced by Putty-Wash Technique
Background and Aims: An accurate impression of teeth and supporting structure is necessary to restore a lost tooth structure or to replace a tooth with crown and bridge. Although there are various methods for making impression, putty-wash technique is currently preferred since it is simple and does not require a special tray. Silicone elastomeric impression materials have suitable consistency f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of international oral health : JIOH
دوره 5 5 شماره
صفحات -
تاریخ انتشار 2013