Influence of single photon emission computed tomography (SPECT) reconstruction algorithm on diagnostic accuracy of parathyroid scintigraphy: Comparison of iterative reconstruction with filtered backprojection
نویسندگان
چکیده
BACKGROUND & OBJECTIVES Preoperative localization of parathyroid lesions is essential for improving the results in patients with primary hyperparathyroidism. The purpose of this study was to evaluate retrospectively the value of technetium-99m (Tc-99m) methoxyisobutylisonitrile (MIBI) single photon emission computed tomography (SPECT) and to compare the diagnostic accuracy of iterative reconstruction (IR) and filtered backprojection (FBP) reconstruction algorithms about localization of parathyroid lesions. METHODS Forty four patients with primary hyperparathyroidism, in whom histopathological correlation could be performed, were included in the study. Dual-phase Tc-99m parathyroid scintigraphy was performed 20 and 120 min after injection of 740 MBq Tc-99m MIBI in all patients. Tomographic images were acquired 120 min after the administration of radiopharmaceutical. The SPECT data were evaluated using an IR as well as a FBP algorithm. In 23 of 44 patients, SPECT acquisitions were performed in 64×64 matrix; in the remaining 21 patients, tomographic data were collected in 128×128 matrix. The imaging results were compared with pathological findings and sensitivities of both reconstruction algorithms, and planar views were calculated. RESULTS Using planar MIBI scans, abnormal parathyroid glands were correctly localized in 75 per cent of the cases. Sensitivity increased to 77 per cent using SPECT with FBP and to 84 per cent with IR. When the sensitivities were calculated according to the acquisition matrix, these were 95 per cent (20/21) and 85 per cent (18/21) for IR and FBP, respectively in patients in whom 128×128 matrix was used. The sensitivities were lower in patients who were imaged with 64×64 matrix; these were calculated as 74 per cent (17/23) and 70 per cent (16/23) with IR and FBP, respectively. INTERPRETATION & CONCLUSIONS Our findings showed that compared to planar scintigraphy, Tc-99m MIBI SPECT was more sensitive diagnostic modality in the detection of abnormal parathyroid tissues. Image quality and sensitivity may be improved further when larger matrices with IR are used instead of FBP algorithm.
منابع مشابه
Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملA new SPECT reconstruction algorithm based on the Novikov explicit inversion formula
We present a new reconstruction algorithm for single-photon emission computed tomography. The algorithm is based on the Novikov explicit inversion formula for the attenuated Radon transform with non-uniform attenuation. Our reconstruction technique can be viewed as a generalization of both the filtered backprojection algorithm and the Tretiak–Metz algorithm. We test the performance of the prese...
متن کاملSPECT-CT fusion in the diagnosis of hyperparathyroidism
Objective(s): In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Methods: Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) we...
متن کاملA non-parametric bootstrap approach for analysing the statistical properties of SPECT and PET images.
Knowledge of the statistical properties of reconstructed single photon emission computed tomography (SPECT) and positron emission tomography (PET) images would be helpful for optimizing acquisition and image processing protocols. We describe a non-parametric bootstrap approach to accurately estimate the statistical properties of SPECT or PET images whatever the noise properties in the projectio...
متن کاملHigh resolution reconstruction for 3D SPECT
In this work, we have developed a new method for SPECT (single photon emission computed tomography) image reconstruction, which has shown the potential to provide higher resolution results than any other conventional methods using the same projection data. Unlike the conventional FBP(filtered backprojection) and EM(expectation maximization) type algorithms, we utilize as much system response in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 145 شماره
صفحات -
تاریخ انتشار 2017