Cone-beam tomography with a digital camera.

نویسندگان

  • D L Marks
  • R Stack
  • A J Johnson
  • D J Brady
  • D C Munson
چکیده

We show that x-ray computer tomography algorithms can be applied with minimal alteration to the three-dimensional reconstruction of visible sources. Diffraction and opacity affect visible systems more severely than x-ray systems. For camera-based tomography, diffraction can be neglected for objects within the depth of field. We show that, for convex objects, opacity has the effect of windowing the angular observation range and thus blurring the reconstruction. For concave objects, opacity leads to nonlinearity in the transformation from object to reconstruction and may cause multiple objects to map to the same reconstruction. In x-ray tomography, the contribution of an object point to a line integral is independent of the orientation of the line. In optical tomography, however, a Lambertian assumption may be more realistic. We derive an expression for the blur function (the patch response) for a Lambertian source. We present experimental results showing cone-beam reconstruction of an incoherently illuminated opaque object.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption

Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...

متن کامل

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.  Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

The Accuracy of Cone-beam Computerized Tomography Linear Measurements in Human Dry Mandible

Background & Aims: The aim of this study was to evaluate the accuracy of Cone-beam Computerized Tomography (CBCT) linear measurements in dry mandibles by comparing them with direct measurements. Methods: Two human dry mandibles were used in this study. Thirteen sites were selected on each mandible. Specimens were scanned by CBCT and linear measurements were made using Planmeca Romexis 2.3.0.R s...

متن کامل

Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)

Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...

متن کامل

The Effect of Intra-Canal Posts on Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography in Detection of Vertical Root Fractures

Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics. Cone Beam Computed Tomography (CBCT)  has significantly enhanced image quality compared to digital radiography (DR) and greatly aids the diagnosis of VRFs but, metal artifacts has remained as a problem in VRF detection.  This study evaluated the effect of intra canal posts on the diagnostic accuracy of CBCT and D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 40 11  شماره 

صفحات  -

تاریخ انتشار 2001