Mapping glucose and lactate concentrations with microliter resolution in rat brain using short-echo-time spectroscopic imaging
نویسندگان
چکیده
Introduction: Short-echo-time (TE) proton spectroscopic imaging is capable not only to map the spatial distribution of NAA, creatine, choline, glutamate/glutamine and myo-inositol but also of metabolites having lower concentrations and/or giving more complex spectral patterns. Glucose (Glc) and lactate (Lac) are compounds which are closely related to energy production in the brain tissue. The spatial distribution of these compounds in brain with microliter resolution (1) can provide information about the function of various brain structures or about brain tumor metabolism (2). The aim of this study was to test the feasibility of measuring distribution of Glc and Lac in the brain of a healthy rat at different plasma Glc levels using short-TE spectroscopic imaging. Experimental: The data were obtained from brain of two adult Sprague-Dawley rats. For inducing hyperglycemia, 20 % Glc solution was infused into the femoral vein at a rate of 0.8 – 2 mL/hour. Plasma Glc levels were measured using an Analox GM7 analyzer (Analox Instruments, MA, USA) and were increased from 6.4 mmol/L (normoglycemia) to 15.0 mmol/L. Metabolic maps were obtained on an actively shielded 9.4 T/31 cm spectrometer (Varian/Magnex Scientific) using a SPECIAL spectroscopy sequence (TR/TE = 2000/2.8 ms) with phase encoding in the horizontal plane (1). A home-built 14 mm diameter quadrature coil was used as a transceiver. Field homogeneity was adjusted by FASTMAP (3). The size of the excited VOI was 9×2×10 mm. Two acquisitions were collected for each of the 32×32 phase encoding steps using FOV of 24 mm×24 mm, giving a nominal voxel size of 0.75×0.75×2 mm (1.1 μL). The k-space data were then filtered with an optimized Hanning function in two spatial domains, thus giving the effective spatial resolution of 1.7 μL (1). Absolute concentrations of metabolites were calculated from the spectra of individual voxels using LCModel (4). Reference water signals were measured using the same protocol without water suppression and with TR=1.5 s. The total measurement time, including both metabolite and water scans, was 2 hours. Results: Fig. 1 shows a VOI, which was phase encoded into 10×12 voxels (Fig. 2). The VOI included mostly hippocampi, striatum and frontal cortex. Total creatine (Cr) was used as an indicator of the measurement stability. Its mean concentration (7.7 – 7.8 mmol/kg) did not change at different plasma Glc concentrations and its distribution was also very stable, with higher levels in hippocampus and cortex than in striatum. With increasing plasma Glc level to 11.1 mmol/L, the mean Glc concentration remained almost the same (from 2.7 to 2.6 mmol/kg) whereas the Lac concentration increased from 1.7 to 2.3 mmol/kg. With further increasing plasma Glc to 15.0 mml/L, the brain Glc concentration raised to 4.8 mmol/kg, whereas Lac slightly dropped to 2.1 mmol/kg. The mean brain Glc concentrations at different plasma Glc levels fell in the range found by C spectroscopy (5). The spatial distribution of Glc and Lac did not vary substantially with Glc infusion: Glc seemed to be highest in cortex, Lac was higher in striatum and hippocampus than in cortex. Discussion and Conclusions: The stable concentration of total creatine suggests an absence of systematic biases during the experiment. Relatively small changes in metabolite concentrations can be clearly seen in their maps. The observed differences in various brain regions agree well with those obtained by single voxel spectroscopy (6). This preliminary study indicates that short-TE proton spectroscopic imaging can be used to measure the spatial distribution of low-concentration metabolites or those with complicated spectral patterns in rat brain with a resolution comparable to PET.
منابع مشابه
An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter
Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...
متن کاملEffects of a phonologically driven treatment for dyslexia on lactate levels measured by proton MR spectroscopic imaging.
BACKGROUND AND PURPOSE Dyslexia is a language disorder in which reading ability is compromised because of poor phonologic skills. The purpose of this study was to measure the effect of a phonologically driven treatment for dyslexia on brain lactate response to language stimulation as measured by proton MR spectroscopic imaging. METHODS Brain lactate metabolism was measured at two different ti...
متن کاملProton echo-planar spectroscopic imaging of J-coupled resonances in human brain at 3 and 4 Tesla.
In this multicenter study, 2D spatial mapping of J-coupled resonances at 3T and 4T was performed using short-TE (15 ms) proton echo-planar spectroscopic imaging (PEPSI). Water-suppressed (WS) data were acquired in 8.5 min with 1-cm(3) spatial resolution from a supraventricular axial slice. Optimized outer volume suppression (OVS) enabled mapping in close proximity to peripheral scalp regions. C...
متن کاملHigh speed 1H spectroscopic imaging in human brain by echo planar spatial-spectral encoding.
We introduce a fast and robust spatial-spectral encoding method, which enables acquisition of high resolution short echo time (13 ms) proton spectroscopic images from human brain with acquisition times as short as 64 s when using surface coils. The encoding scheme, which was implemented on a clinical 1.5 Tesla whole body scanner, is a modification of an echo-planar spectroscopic imaging method ...
متن کاملNon‐water‐suppressed short‐echo‐time magnetic resonance spectroscopic imaging using a concentric ring k‐space trajectory
Water-suppressed MRS acquisition techniques have been the standard MRS approach used in research and for clinical scanning to date. The acquisition of a non-water-suppressed MRS spectrum is used for artefact correction, reconstruction of phased-array coil data and metabolite quantification. Here, a two-scan metabolite-cycling magnetic resonance spectroscopic imaging (MRSI) scheme that does not ...