Simultaneous determination of rosuvastatin and amlodipine in human plasma using tandem mass spectrometry: Application to disposition kinetics

نویسندگان

  • Anjaneyulu Narapusetti
  • Syama Sundar Bethanabhatla
  • Anbazhagan Sockalingam
  • Nagakishore Repaka
  • Veldandi Saritha
چکیده

The liquid chromatography-tandem mass spectrometric assay method for the simultaneous determination of rosuvastatin and amlodipine in human plasma using deuterated analogs as internal standards has been developed and validated. The analytes were extracted from 100 μL aliquots of human plasma via liquid-liquid extraction using a mixture of ethyl acetate and n-hexane (80:20, v/v) as an extraction solvent. The optimized mobile phase was composed of 0.1% formic acid in 5 mM ammonium acetate, methanol, and acetonitrile (20:20:60, v/v/v) and delivered at a flow rate of 0.75 mL/min. The calibration curve obtained was linear (R (2) ⩾ 0.999) over the concentration range of 0.52-51.77 ng/mL for rosuvastatin and 0.10-10.07 ng/mL for amlodipine. A sample turnover rate of less than 2.5 min makes it an attractive procedure in high-throughput bioanalysis of rosuvastatin and amlodipine. The present method was found to be applicable to clinical studies and the results were authenticated by incurred sample reanalysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

A quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...

متن کامل

Validated LC-MS/MS Method for the Determination of Rosuvastatin in Human Plasma: Application to a Bioequivalence Study in Chinese Volunteers

A sensitive and selective liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of rosuvastatin in human plasma using gliclazide as an internal standard (IS). Rosuvastatin and gliclazide in plasma were extracted with ethyl acetate, separated on a C18 reversed phase column, eluted with mobile phase of acetonitri...

متن کامل

Determination of Mebudipine in Human Plasma by Liquid Chromatography–tandem Mass Spectrometry

In previous studies, mebudipine, a dihydropyridine calcium channel blocker, showed a considerable potential to be used in cardiovascular diseases. The aim of the current study was to develop a valid method using reversed-phase high performance liquid chromatography coupled with electrospray ionization mass spectrometry to assay mebudipine in the human plasma. Separation was achieved on a Zorbax...

متن کامل

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2015