Novel sutureless transplantation of bioadhesive-coated, freeze-dried amniotic membrane for ocular surface reconstruction.

نویسندگان

  • Eiichi Sekiyama
  • Takahiro Nakamura
  • Eiji Kurihara
  • Leanne J Cooper
  • Nigel J Fullwood
  • Maho Takaoka
  • Junji Hamuro
  • Shigeru Kinoshita
چکیده

PURPOSE To evaluate the efficacy and safety of a novel sutureless transplantation of bioadhesive-coated, sterilized, freeze-dried amniotic membrane (FD-AM) for ocular surface reconstruction. METHODS A bioadhesive-coated, freeze-dried amniotic membrane was made by freeze drying the denuded AM in a vacuum, applying the minimum amount of fibrin glue (mixture of fibrinogen and thrombin) necessary to retain adhesion on the chorionic side, and sterilizing it by gamma-radiation. The resultant AM was characterized for its biological and morphologic properties by immunohistochemical and electron microscopic examination. In addition, fibrin glue-coated, freeze-dried (FCFD) AM was transplanted onto a rabbit scleral surface without sutures, to examine its biocompatibility. RESULTS Immunohistochemistry of the FCFD-AM revealed that fibrinogen existed on its chorionic side, and the process of applying fibrin glue did not affect its biological and morphologic properties. Moreover, electron microscopic examination of the chorionic side of the FCFD-AM revealed tiny microfibrils (which are probably fibrinogen protofibrils), and showed that the epithelial surface of FCFD-AM consisted of intact basal lamina similar to that of FD-AM. FCFD-AM transplantation was very easily performed, and the graft adhered to the bare sclera immediately. Though the fibrinogen naturally biodegraded within 2 weeks, the FCFD-AM remained for at least 12 weeks after transplantation. Epithelialization on the FCFD-AM was achieved within 2 weeks, as was the case with FD-AM transplantation. The conjunctival epithelium on the FCFD-AM was well stratified and not keratinized, suggesting that FCFD-AM supports normal cell differentiation. CONCLUSIONS The FCFD-AM retained most of the biological characteristics of FD-AM. Consequently, this sutureless method of transplantation of FCFD-AM is safe, simple, and useful for ocular surface reconstruction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sterilized, freeze-dried amniotic membrane: a useful substrate for ocular surface reconstruction.

PURPOSE To examine the feasibility of using sterilized, freeze-dried amniotic membrane (FD-AM) as a substrate for cultivating autologous corneal epithelial cells for ocular surface reconstruction. METHODS Human AM deprived of amniotic epithelial cells by incubation with EDTA was freeze dried, vacuum packed, and sterilized with gamma-irradiation. The resultant FD-AM was characterized for its p...

متن کامل

The Effect of Lyophilization on Light Transmission of Amniotic Membrane: A Comparison with Rabbit Cornea

Background & Aims: Amniotic membrane persists for a long time after ocular transplantation (as corneal substitute) and can affect light transmission (transparency). The aim of this study was to evaluate the transparency of amniotic membrane after freeze-drying (lyophilization) and to compare the results with transparency of rabbit cornea. Methods: Transparency of rabbits’ corneas and fresh and ...

متن کامل

Assessment of the use of cryopreserved x freeze-dried amniotic membrane (AM) for reconstruction of ocular surface in rabbit model.

PURPOSE To determine the efficacy of freeze-dried amniotic membrane (AM) for reconstruction of the ocular surface in rabbit eyes. METHODS The sterilized, freeze-dried amniotic membrane (lyophilized or FD-AM) is a preservative method that uses the drying by freezing process to maintain the AM well preserved for a long time even at room temperature. This paper is an experimental animal interven...

متن کامل

Sutureless Fixation of Amniotic Membrane for Therapy of Ocular Surface Disorders

Amniotic membrane is applied to the diseased ocular surface to stimulate wound healing and tissue repair, because it releases supportive growth factors and cytokines. These effects fade within about a week after application, necessitating repeated application. Generally, amniotic membrane is fixed with sutures to the ocular surface, but surgical intervention at the inflamed or diseased site can...

متن کامل

Amniotic membrane transplantation (AMT) without the use of sutures/fibrin glue.

INTRODUCTION Amniotic membrane transplantation (AMT) has been used for a wide variety of ocular surface problems. Current techniques for the AMT involve suturing of the graft or patch over the ocular surface or use of fibrin glue. OBJECTIVE To describe a new sutureless technique of amniotic membrane transplantation (AMT) without the use of sutures/fibrin glue. MATERIALS AND METHODS Amniotic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 48 4  شماره 

صفحات  -

تاریخ انتشار 2007