Setting and Algorithm Simulation of Pv Anti-islanding Protection in Case of Increased Frequency Threshold
نویسندگان
چکیده
UOVR and UOFR as passive anti-islanding methods lack of sensitivity to detect islanding. The performance gets worse when the frequency threshold is increased from 50.2 Hz to 50.6 Hz. For instance, dedicated passive methods such as ROCOF help the inverter to detect islanding. When active methods such as SFS and SVS are activated, the number of detected islandings is increased to 87.5%. To improve the number of detected islanding and to reduce the number of false trippings, an under voltage blocking scheme and zero crossing detection are implemented. As results, the inverter could detect 100% of islanding event with 13.3% of false tripping. As future work to reduce the number of false tripping, a study implementing impedance measurement with a closed loop simulation could be done.
منابع مشابه
Implementation of ROCOPS Method for Anti-Islanding Protection of Wind Turbine
In recent years, based on the growing importance of clean energy in comparison with conventional energy production from fossil fuels, DG systems are gradually becoming more popular all over the world. These resources solve many problem of system. However, these resources create some other problems too. One of the most problem of DGs is unwanted islanding. This paper addresses reliable passive i...
متن کاملA Test Device for Optimize PMU-based Islanding Detection Technology
Islanding detection is a necessary function for grid connected distributed generators. Usually, islanding detection methods can be classified as two catalogues: remote detecting methods and local detecting methods. Most of them have limitation and defects when they are applied in photovoltaic power stations. Recently synchronous phasor measuring units (PMU) is proposed to be applied for islandi...
متن کاملروشی جدید در تحلیل عملکرد حفاظت های ضدجزیره ای فرکانسی در حالت جزیرهای چند اینورتری
Because of high penetration of distributed resources in the distribution networks, the analysis of islanding protection in the multiple inverters situation has become of a great importance. In this paper a new method which analyzes the frequency based anti-islanding protection in the multiple inverters situation, is presented. The method has wide domain of applicability and analyzes the operati...
متن کاملAnti-islanding protection based on voltage and frequency analysis in wind turbines units
This paper introduces a new islanding detection algorithm method based on voltage and frequency analysis for wind turbines as distributed resource units at the distribution voltage level. The proposed method is based on processing of the rate of change of q-axis component of voltage and accelerates of change of frequency. This method detects the islanding conditions with the analysis of these s...
متن کاملA Hybrid Anti-islanding Method for Inverter-Based Distributed Generation
Nowadays, high penetration of Distributed Generations (DG)s in power systems caused some protection issues. One of these issues is unintentional islanding. As regards IEEE 1547 standard, this situation must be recognized immediately, and DG must be separated from the load in less than 2 seconds. In this paper, to detection of islanding in an inverter-based distributed generation, a new hybrid m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015